English
Language : 

0031.1623 Datasheet, PDF (1/2 Pages) Schurter Inc. – Shock-Safe Fuseholder, 5 x 20 / 6.3 x 32 mm, Slot Knob/Fingergrip, IEC: 500 VAC, UL/CSA: 600 VAC/DC
Fuseholders
www.schurter.com/pg02
Shock-Safe Fuseholder, 5 x 20 / 6.3 x 32 mm, Slot Knob/Fingergrip, IEC: 500 VAC, UL/CSA: 600 VAC/DC
FEC
500 VAC · 4 W / 10 A (VDE) · 600 VAC/DC · 20 A (UL/CSA)
Description
- Fuseholder for 500 VAC applications
- Cap is available slotted or fingergrip
Standards
- IEC 60127-6
- UL 4248-1
- CSA 22.2 no. 4248-1
Approvals
- VDE Certificate Number: 137910
- UL File Number: E39328
- CSA File Number: 38456
Technical Data
Shocksafe Category
Fuse-Link
Mounting
Mounting
Terminal
Rated Voltage
Rated Current
Rated Power Acceptance IEC
Degree of Protection
Protection Class
Admissible Ambient Air Temp.
Climatic Category
Material: Socket
Material: Terminals
Unit Weight (Socket/Cap)
Storage Conditions
Product Marking
PC2
5 x 20 or 6.3 x 32 mm
Panel Mount, Front-Side
Fixing Nut
Solder or Quick-Connect 6.3 x 0.8 mm
500 VAC (VDE), 600 VAC/DC (UL/CSA)
10 A (VDE), 20 A (UL/CSA)
4 W / 10 A @ Ta 23 °C
Admissible power acceptance at hig-
her ambient temperature see derating
curves
IP 40
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
-40 °C to 85 °C
40/085/21 acc. to IEC 60068-1
Thermoset, black, UL 94V-0
Tin-Plated Copper Alloy
9 g / 5.36 g
0 °C to 60 °C, max. 70% r.h.
, Type, Voltage, Power Acc./Current
Rating, Approvals
Applications
- Equipment with three-phase supply (400 VAC)
- Industrial electronic
Weblinks
pdf, html, General Product Information, Approvals, RoHS, CHINA-
RoHS, e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check,
Accessories
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Admissible Torque on Fixing
Nut
Panel Thickness s
Iron
350 °C / 2 sec acc. to IEC 60068-2-20,
Test Ta, method 2
350 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 2
< 5 mΩ at 20 mV
> 3 kV between L-N
> 4 kV between L/N-PE
(50 Hz; 1 min)
> 4 kV between L-N
> 6 kV between L/N-PE
> 10 MΩ between L-N
> 100 MΩ between L/N-PE
(500 VDC; 1 min)
I - III acc. to IEC 60664-1
2 acc. to IEC 60664-1
max 1.2 Nm
max 9 mm
Dimensions
56.5 mm
max. 9 (CSA: max. 4)
SW14
max. 9 (CSA: max. 4)
SW14
M16x2/2
8
4
45
21.9
56.5
Variant with slot knob 0031.1631 + 0031.1611/1613
M16x2/2
21.9
4
45
56.5
Variant Fingergrip 0031.1631 + 0031.1616
Fuses