English
Language : 

SBX201C Datasheet, PDF (3/3 Pages) Sanyo Semicon Device – Schottky Barrier Diode S to X-Band Detector, Mixer Applications
S11 Parameters
V=0V/I=0mA
Freq(GHz)
1.00
⏐S11⏐
0.996
∠S11
-8.9
2.00
0.992
-18.4
3.00
0.987
-30.0
4.00
0.975
-44.8
5.00
0.958
-63.9
6.00
0.944
-89.0
7.00
0.928
237.1
8.00
0.909
195.8
9.00
0.910
153.3
10.00
0.927
116.3
11.00
0.925
88.9
12.00
0.922
70.5
13.00
0.929
56.1
14.00
0.919
42.7
15.00
0.897
30.9
16.00
0.879
20.8
17.00
0.872
13.1
18.00
0.855
5.1
SBX201C
V=0V/I=0.1mA
⏐S11⏐
0.844
∠S11
-8.9
0.811
-18.6
0.800
-30.6
0.766
-46.7
0.696
-67.8
0.634
264.7
0.566
227.1
0.538
180.8
0.570
135.1
0.646
100.6
0.734
75.9
0.771
62.0
0.814
49.6
0.828
38.0
0.831
27.2
0.843
17.8
0.834
10.7
0.826
3.1
V=0V/I=0.5mA
⏐S11⏐
0.381
∠S11
-2.6
0.314
-3.7
0.289
-8.8
0.208
-12.0
0.127
12.0
0.170
54.5
0.274
62.6
0.372
60.7
0.465
54.2
0.541
47.4
0.608
42.1
0.651
37.3
0.694
31.8
0.717
24.7
0.731
17.8
0.753
11.9
0.760
5.1
0.764
-1.2
V=0V/I=1.0mA
⏐S11⏐
0.092
∠S11
64.4
0.177
82.0
0.251
76.7
0.326
73.6
0.403
68.5
0.477
62.3
0.537
55.9
0.586
49.5
0.630
42.8
0.666
36.5
0.694
31.7
0.717
27.6
0.735
22.9
0.740
17.0
0.736
11.1
0.739
6.2
0.750
0.1
0.750
-5.4
V=0V/I=5mA
⏐S11⏐
0.459
∠S11
148.1
0.517
122.2
0.582
102.8
0.642
87.7
0.691
75.0
0.730
64.3
0.758
55.3
0.780
47.2
0.798
39.4
0.809
32.3
0.818
26.8
0.828
22.5
0.833
17.3
0.821
11.2
0.800
5.1
0.787
-0.1
0.792
-5.9
0.780
-11.5
SANYO Semiconductor Co.,Ltd. assumes no responsibility for equipment failures that result from using
products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition
ranges, or other parameters) listed in products specifications of any and all SANYO Semiconductor Co.,Ltd.
products described or contained herein.
SANYO Semiconductor Co.,Ltd. strives to supply high-quality high-reliability products, however, any and all
semiconductor products fail or malfunction with some probability. It is possible that these probabilistic failures or
malfunction could give rise to accidents or events that could endanger human lives, trouble that could give rise
to smoke or fire, or accidents that could cause damage to other property. When designing equipment, adopt
safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not
limited to protective circuits and error prevention circuits for safe design, redundant design, and structural
design.
In the event that any or all SANYO Semiconductor Co.,Ltd. products described or contained herein are
controlled under any of applicable local export control laws and regulations, such products may require the
export license from the authorities concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system, or otherwise,
without the prior written consent of SANYO Semiconductor Co.,Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the "Delivery Specification" for the
SANYO Semiconductor Co.,Ltd. product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed
for volume production.
Upon using the technical information or products described herein, neither warranty nor license shall be granted
with regard to intellectual property rights or any other rights of SANYO Semiconductor Co.,Ltd. or any third
party. SANYO Semiconductor Co.,Ltd. shall not be liable for any claim or suits with regard to a third party’s
intellectual property rights which has resulted from the use of the technical information and products mentioned
above.
This catalog provides information as of July, 2008. Specifications and information herein are subject
to change without notice.
PS No. A0628-3/3