English
Language : 

LC75836W Datasheet, PDF (12/18 Pages) Sanyo Semicon Device – 1/4-Duty General-Purpose LCD Display Driver
LC75836W
5. BU: Normal mode/power-saving mode control data
This control data bit selects either normal mode or power saving mode.
BU
Mode
0
Normal mode
Power saving mode.
In RC oscillator operating mode (OC = 0), the OSC pin oscillator is stopped, and in external clock operating mode
1
(OC = 1), acceptance of the external clock is stopped. In this mode the common and segment output pins go to the
VSS levels. However, S1/P1 to S4/P4 output pins that are set to be general-purpose output ports by the control data
P0 to P2 can be used as general-purpose output ports.
No.A0428-12/18