MPM01 Datasheet, PDF (7/12 Pages) Sanken electric – Io=3A non-isorated step-down DC/DC Converter module
Io=3A non-isorated step-down DC/DC Converter module
MPM00 Series
Jul/10/2013
About thermal derating curve of output current *It is a setup of commonness of MPM01/04.
Thermal derating curve of the figure 6 is without the radiator which is a standard use condition fundamentally of MPM01/04.
By the use of cooling-fan / radiator installation, output current beyond 3A can't be agreed.
OCP(overcurrent protection) threshold value can't be changed, because it is fixed by built-in MIC.
*With package design of MPM00, though radiator installation is possible by the screw, keep the following strictly:
1) You must surely use load current with less than 3Amps.
2) You must use the radiator of the form that package surface temperature is less than 100℃.
(But, ambient temperature "Ta" makes 85℃ an upper limit.)
Block diagram *It is a setup of commonness of MPM01/04.
MPM01
3704
①
⑨
fig.7
fig.8
Pin assign & function/name
Table 5
Terminal
number
symbol
Functions/names
①
GND Ground terminal
②
VIN Input power supply terminal
③
GND Ground terminal
④
FB Feedback terminal/resistor RFB connection terminal for output voltage setting
⑤⑥⑦
OUT Output terminal
⑧⑨
SW Oscillating frequency measurement terminal (15)
(15) The "SW" terminal is for the measurement(switching frequency) in the manufacture process. Connect nothing
on the circuit board in case of use.
*Confirm a terminal number referring to the fig.8.
Rev.1.0
SANKEN ELECTRIC CO., LTD.
7