English
Language : 

NR885E Datasheet, PDF (3/12 Pages) Sanken electric – Synchronous Buck Regulator
3A, 18V, 350kHz , Synchronous Buck Regulator
NR885E
Oct./30/2013
Electrical Characteristics
Parameter
Reference voltage
Output voltage temperature
coefficient
Switching frequency
Symbol
VREF
⊿VREF/⊿T
MIN
0.784
―
fSW
280
Line regulation
(8)
VLine
―
Load regulation
Over current protection
threshold
Supply Current
(8)
VLoad
―
IS
3.1
IIN
―
Shutdown Supply Current
IIN(off)
0
SS Pin
Source current
at low level
voltage
High level
voltage
IEN/SS
6
VSSH
―
EN Pin
Sink current
Threshold voltage
IEN
VC/EH
0.7
Max on-duty
(8)
DMAX
―
Minimum on-time
(8)
(9)
TON(MIN)
―
Thermal shutdown threshold
temperature
(8)
TSD
151
Thermal shutdown
restart hysteresis
(8) TSD_hys
―
of temperature
(8) Guaranteed by design, not tested.
(9) The I/O characteristic are limited by the TON(MIN).
Ratings
TYP
0.800
±0.05
350
50
50
―
6
―
MAX
0.816
―
420
―
―
6.0
―
10
Ta = 25°C
Units
Test conditions
V VIN = 12V,IO = 1.0A
mV/°C
VIN = 12V, IO = 1.0A
40°C to +85°C
kHz
VIN =12V, VO=3.3V,
IO =1A
mV VIN = 6.3V~18V,
VO = 3.3V, IO = 1A
mV
VIN = 12V, VO = 3.3V,
IO = 0.1A~3.0A
A VIN = 12V, VO = 3.3V
mA
VIN = 12V
VEN=10kΩ pull up to VIN
μA
VIN =12V, IO =0A,
VEN=0V
10
14
μA VSS=0V, VIN=12V
3.0
―
V VIN =12V
50
100
μA VEN= 10V
1.4
2.1
V VIN =12V
90
―
%
150
―
nsec
165
―
°C
20
―
°C
Rev.1.1
SANKEN ELECTRIC CO., LTD.
3