NR131A Datasheet, PDF (3/15 Pages) Sanken electric – Ultra light load high efficiency
Ultra light load high efficiency,VIN=17V,Current mode Step-down Io=3A Buck Regulator IC
NR130A series
Tentative
Sep/10/2013
(3) Limited by thermal shutdown.
(4) The temperature detection of thermal shutdown is about 165°C
Recommended Operating Conditions
Parameter
Symbol
DC input voltage
DC output current
(5)
VIN
(6)
(7)
IO
Ratings
MIN
MAX
Vo+3
17
0
3.0
Units
V
A
Output voltage
VO
0.8
14
V
Ambient operating temperature
(7)
TOP
40
85
°C
(5) The minimum value of input voltage is taken as the larger one of either 4.5V or VO +3V.
In the case of VIN=VO +1~VO +3V , it is set to IO = Max. 2A
(6) Recommended circuit refers to Typical Application Circuit.
(7) To be used within the allowable package power dissipation characteristics.
Conditions
Rev.1.1
SANKEN ELECTRIC CO., LTD.
3
http://www.sanken-ele.co.jp