English
Language : 

SMA6863M Datasheet, PDF (1/13 Pages) Sanken electric – High Voltage 3-Phase Motor Driver
SMA6863M
High Voltage 3-Phase Motor Driver
Features and Benefits
▪ Built-in pre-drive IC
▪ MOSFET power element
▪ Alleviate noise generation by adjusting an internal resistor
▪ CMOS compatible input (5 V)
▪ High-side gate driver using bootstrap circuit or floating
power supply
▪ Built-in protection circuit for controlling power supply
voltage drop (UVLO on VCC)
▪ Overcurrent protection (OCP), overcurrent limiting (OCL),
and thermal shutdown (TSD)
▪ Output of fault signal during operation of protection circuit
▪ Output current 2.5 A
▪ Small SIP (SMA 24-pin)
Packages: Power SIP
Not to scale
Leadform
2451
Leadform
2452
Description
The SMA6863M inverter power module (IPM) device provides
a robust, highly-integrated solution for optimally controlling
3-phase motor power inverter systems and variable speed
control systems used in energy-conserving designs to drive
motors of residential and commercial appliances. These ICs
take 230 VAC input voltage, and 2.5 A (continuous) output
current. They can withstand voltages of up to 500 V (MOSFET
breakdown voltage).
The SMA6800M power package includes an IC with all of
the necessary power elements (six MOSFETs), pre-driver ICs
(two), and bootstrap diodes (three), needed to configure the
main circuit of an inverter. This enables the main circuit of
the inverter to be configured with fewer external components
than traditional designs.
Applications include residential white goods (home
applications) and commercial appliance motor control:
• Air conditioner fan
• Refrigerator compressor
• Dishwasher pump
Functional Block Diagram
VB1 VB2 VB3
VCC1
UVLO
UVLO UVLO UVLO
VBB
HIN 1
HIN 2
HIN 3
COM1
SD1
VCC 2
LIN1
LIN2
LIN3
COM2
SD2
OCL
RC
Figure 1. Driver block diagram.
Input
Logic
High-Side
Level Shift Driver
W1
W2
V
U
UVLO
Input Logic
(OCP Reset )
Low-Side
Driver
Thermal
Shutdown
OCP
LS 1
OCP and OCL
LS2
A. SD1, SD2 terminals are used for both input and output.
B. SD1, SD2, and OCL terminals are open-collector output. RC terminal is open-drain output.
C. Blanking Time (tblank) is used in Overcurrent Limiting (OCL) and Overcurrent Protection (OCP).
If the time exceeds the limit, the signal will be output (open-collector output turns on), and protection
operation will start up.