English
Language : 

SMA6860MZ Datasheet, PDF (1/19 Pages) Sanken electric – High Voltage 3-Phase Motor Drivers
SMA6860MZ Series
High Voltage 3-Phase Motor Drivers
Features and Benefits
▪ Built-in pre-drive IC
▪ MOSFET power element
▪ Alleviate noise generation by adjusting an internal resistor
▪ CMOS compatible input (5 V)
▪ High-side gate driver using bootstrap circuit or floating
power supply
▪ Built-in protection circuit for controlling power supply
voltage drop (UVLO on VB and VCC)
▪ Overcurrent protection (OCP), overcurrent limiting (OCL),
and thermal shutdown (TSD)
▪ Output of fault signal during operation of protection circuit
▪ Output current 1.5, 2, or 2.5 A
▪ Small SIP (SMA 24-pin)
Packages: Power SIP
Not to scale
Leadform
2451
Leadform
2452
Description
The SMA6860MZ inverter power module (IPM) series provides
a robust, highly-integrated solution for optimally controlling
3-phase motor power inverter systems and variable speed
control systems used in energy-conserving designs to drive
motors of residential and commercial appliances. These ICs
take 230 VAC input voltage, and up to 2.5 A (continuous)
output current. They can withstand voltages of up to 500 V
(MOSFET breakdown voltage).
The SMA6860MZ power package includes an IC with all of
the necessary power elements (six MOSFETs), pre-driver ICs
(two), and bootstrap diodes (three), needed to configure the
main circuit of an inverter. This enables the main circuit of
the inverter to be configured with fewer external components
than traditional designs.
Applications include residential white goods (home
applications) and commercial appliance motor control:
• Air conditioner fan
• Small ventilation fan
• Dishwasher pump
VCC1
HIN 1
HIN 2
HIN 3
COM1
SD1
VCC 2
LIN1
LIN2
LIN3
COM2
SD2
OCL
RC
Figure 1. Driver block diagram
SMA6860MZ-DS, Rev. 5
Functional Block Diagram
VB1 VB2 VB3
UVLO
Input
Logic
UVLO UVLO UVLO
High-Side
Level Shift Driver
UVLO
Input Logic
(OCP Reset )
Low-Side
Driver
Thermal
Shutdown
OCP
OCP and OCL
VBB
W1
W2
V
U
LS2
LS1
A. ¯S¯¯D¯¯1¯ and ¯S¯¯D¯¯2¯ terminals are used for both input and output.
B. ¯S¯¯D¯¯1¯, ¯S¯¯D¯¯2¯, and ¯O¯¯C¯¯L¯terminals are open-collector output. RC terminal is open-drain output.
C. Blanking Time (tblank) is used in Overcurrent Limiting (OCL) and Overcurrent Protection (OCP).
If the time exceeds the limit, the signal will be output (open-collector output turns on) on the ¯S¯¯D¯¯2¯
pin, and protection operation will start up.
SANKEN ELECTRIC CO., LTD.
http://www.sanken-ele.co.jp/en/