English
Language : 

SDH04 Datasheet, PDF (1/2 Pages) Sanken electric – Surface-mount Dual Circuit High-side Power Switch Array
Surface-mount Dual Circuit High-side Power Switch Array SDH04
Features
q Built-in diagnostic function to detect short and open circuiting of loads and
output status signals
q Low saturation PNP transistor use
q Allows direct driving using LS-TTL and C-MOS logic levels
q Built-in overcurrent and thermal protection circuits
q Built-in protection against reverse connection of power supply
q Tj = 150ºC guaranteed
q Surface-mount full-mold package
Absolute Maximum Ratings
Parameter
Symbol
Power supply voltage
Drive terminal applied voltage
Input terminal voltage
DIAG output applied voltage
DIAG output source current
Voltage across power supply
and drive terminal
Output current
Power dissipation
Junction temperature
Operating temperature
Storage temperature
VB
VD
VIN
VDIAG
IDIAG
VB–D
IO
PD
Tj
TOP
Tstg
Ratings
–13 to +40
–0.3 to VB
–0.3 to +7.0
–0.3 to +7.0
3
VB –0.4
1.5
2.6
–40 to +150
–40 to +100
–40 to +150
(Ta=25ºC)
Unit
Conditions
V
V
V
V
mA
V
A
W
Without heatsink, all circuits operating
ºC
ºC
ºC
Electrical Characteristics
Parameter
Symbol
min
Operating power supply voltage VBopr
6.0
Quiescent circuit current
Iq
Threshold input voltage
VINth
0.8
Hi output
IIN
Input current
Lo output
IIN
0
Saturation voltage of output
transistor
VCE (sat)
Output terminal sink current
IO (off)
Saturation voltage of DIAG output
VDL
Leak current of DIAG output
IDGH
Open load detection resistor Ropen
1
Overcurrent protection starting
IS
1.6
current
Thermal protection starting
TTSD
150
temperature
Output transfer time
TON
TOFF
DIAG output transfer time
TPLH
TPHL
(VBopr =14V, Ta=25ºC unless otherwise specified)
Ratings
Unit
typ
max
Conditions
16
V
5
12
mA
Lo output
3.0
V
1.0
mA
VIN = 5V
100
µA
VIN = 0V
0.5
V
IO 1.0A, VBopr = 6 to 16V
2.0
mA
VO = 0V, VIN = 0V
0.3
V
IDIAG = 3mA
100
µA
VDIAG = 5V
30
kΩ
A
VO = VBopr –1.9V
ºC
VBopr 6V
8
30
µS
IO = 1A
15
30
µS
IO = 1A
10
30
µS
IO = 1A
15
30
µS
IO = 1A
Note: * The rule of protection against reverse connection of power supply is VB = –13V, one minute
(all terminals except, VB and GND, are open).
Diagnostic Function
External Dimensions (unit: mm) SMD-16A
0.25
0.89 ±0.15 2.54 ±0.25
+0.15
0.75 –0.05
16
9
a
b
+0.15
0.3 –0.05
Pin 1
20.0max
8
19.56 ±0.2
a: Type No.
b: Lot No.
Equivalent Circuit Diagram
The MIC is bound by the dotted lines.
2
IN1
3
DIAG1
Pre. Reg.
CONT.
11kΩ typ.
DIAG DET.
Drive
O.C.P
T.S.D
9,12,16
* VB 2
* 1,15 Out1 2
* 14 D1 1
IN2 7
DIAG2 6
CONT.
11kΩ typ.
DIAG DET.
[Abbreviations]
Drive: Drive circuit
CONT: ON/OFF circuit
Pre.Reg: Pre-regulator
Drive
O.C.P
4,5,13
*2
GND
* 8,10 Out2 2
* 11 D2 1
DIAG.DET.: Diagnostic circuit
O.C.P.: Overcurrent protection
T.S.D.: Thermal protection
*1. The base terminal (D terminal) is connected to the output
transistor base. It is also connected to the control monolithic
IC. Do not, therefore, apply an external voltage in operation.
*2. SDH04 have two or three terminals of the same function (VB,
Out1, Out 2, GND). The terminals of the same function must be
shorted at a pattern near the product.
Standard Circuit Diagram
VB
PZ
D1
Out
SDH04
VCC
IN
DIAG
5.1kΩ
30
VB
GND
GND VIN
3.0V
0.8V
GND VOUT
IO
SHORT
Is
OVER
VOLTAGE
OPEN OPEN
TSD
GND VDIAG
Normal Shorted load Open load
Overvoltage Overheat
ERROR SIGNAL for CPU
Truth table
VIN
VO
H
H
L
L
GND
Note 1: A pull-down resistor (11 kΩ typ.) is connected to the IN terminal.
VOUT turns "L" when a high impedance is connected to the IN terminal in
series.