DKI04035 Datasheet, PDF (1/6 Pages) Sanken electric – DC-DC converters | |||
|
40 V, 48 A, 3.3 mΩ Low RDS(ON)
N ch Trench Power MOSFET
DKI04035
Features
ï¬ V(BR)DSS --------------------------------- 40 V (ID = 100 µA)
ï¬ ID ---------------------------------------------------------- 48 A
ï¬ RDS(ON) ------------ 4.3 mΩ max. (VGS = 10 V, ID = 51 A)
ï¬ Qg------26.4 nC (VGS = 4.5 V, VDS = 20 V, ID = 58.5 A)
ï¬ Low Total Gate Charge
ï¬ High Speed Switching
ï¬ Low On-Resistance
ï¬ Capable of 4.5 V Gate Drive
ï¬ 100 % UIL Tested
ï¬ RoHS Compliant
Package
TO-252
(4)
D
(1) (2) (3)
GDS
(3) (2) (1)
SDG
Applications
ï¬ DC-DC converters
ï¬ Synchronous Rectification
ï¬ Power Supplies
Equivalent circuit
D(2)(4)
G(1)
S(3)
Not to scale
Absolute Maximum Ratings
ï· Unless otherwise specified, TA = 25 °C
Parameter
Symbol
Test conditions
Rating
Unit
Drain to Source Voltage
VDS
40
V
Gate to Source Voltage
VGS
± 20
V
Continuous Drain Current
ID
TC = 25 °C
48
A
Pulsed Drain Current
IDM
PW ⤠100µs
Duty cycle ⤠1 %
96
A
Continuous Source Current
(Body Diode)
IS
48
A
Pulsed Source Current
(Body Diode)
ISM
PW ⤠100µs
Duty cycle ⤠1 %
96
A
VDD = 20 V, L = 1 mH,
Single Pulse Avalanche Energy
EAS
IAS = 11.2 A, unclamped,
RG = 4.7 Ω
126
mJ
Refer to Figure 1
Avalanche Current
IAS
23.3
A
Power Dissipation
PD
TC = 25 °C
Operating Junction Temperature
TJ
Storage Temperature Range
TSTG
* When mounted on 1 inch square 2 oz copper pad on 1.5 Ã 1.5 inch.
61
W
150
°C
â 55 to 150
°C
DKI04035-DS Rev.1.2
SANKEN ELECTRIC CO.,LTD.
1
Jan. 20, 2014
http://www.sanken-ele.co.jp
|
▷ |