English
Language : 

S6C1652 Datasheet, PDF (7/19 Pages) Samsung semiconductor – 6 BIT 300 / 309 CHANNEL TFT-LCD SOURCE DRIVER
6 BIT 300 / 309 CHANNEL TFT-LCD SOURCE DRIVER
S6C1652
PIN DESCRIPTIONS
Symbol
Pin Name
Description
VDD1
Logic power supply 2.7 - 3.6 V
VDD2
Driver power supply 6.4 - 13.0 V
VSS1
Logic ground
Ground (0 V)
VSS2
Driver ground
Ground (0 V)
Y1 - Y309
Driver outputs
The D/A converted 64 gray-scale analog voltage is output.
D0<0:5>
- D2<0:5>
Display data input
The display data is input with a width of 18 bits,
gray-scale data (6 bits) by 3 dots (R,G,B) DX0: LSB, DX5: MSB
This pin controls the direction of shift register in cascade connection.
SHL
Shift
direction control input
The shift direction of the shift registers is as follows.
SHL = H: DIO1 input, Y1 → Y309, DIO2 output
SHL = L: DIO2 input, Y309 → Y1, DIO1 output
DIO1
Start pulse input / output
SHL = H: Used as the start pulse input pin
SHL = L: Used as the start pulse output pin
DIO2
Start pulse input / output
SHL = H: Used as the start pulse output pin
SHL = L: Used as the start pulse input pin
POL
Polarity input
POL = H: The reference voltage for odd number outputs are VGMA1 –
VGMA9 and those for even number outputs are VGMA10 – VGMA18
POL = L: The reference voltage for odd number outputs are VGMA10
– VGMA18 and those for even number outputs are VGMA1 – VGMA9
CLK2
Shift clock input
Refer to the shift register's shift clock input. The display data is loaded
to the data register at the rising edge of CLK2.
CLK1
Latch input
Latches the contents of the data register at rising edge and transfers
them to the D/A converter. Also, after CLK1 input, clears the internal
shift register contents. After 1 pulse input on start, operates normally.
CLK1 input timing refers to the "Relationships between CLK1 start
pulse (DIO1, DIO2) and blanking period" of the switching characteristic
waveform. Outputs the gray-scale data at rising edge.
VGMA1
–
VGMA18
Gamma corrected power
supplies
Input the gamma corrected power supplies from external source.
VDD2 > VGMA1 > VGMA2 > ……… > VGMA17 > VGMA18 > VSS2
Keep gray-scale power supply unchanged during the gray-scale
voltage output.
SELT
Output selection input
SELT = H: 300 Output (Y151 - Y159 are disabled)
SELT = L: 309 Output
TESTB
Test input
TESTB = H: Normal operation mode
TESTB = L: Test mode (OP AMP CUT-OFF, Rpu = 30kΩ)
7