English
Language : 

SA9108F Datasheet, PDF (6/12 Pages) Sames – TWO PHASE BIDIRECTIONAL POWER/ENERGY METERING IC WITH INSTANTANEOUS PULSE OUTPUT
SA9108F
2. Analog Input Configuration
The current and voltage sensor inputs are illustrated below.
These inputs are protected against electrostatic discharge through clamping
diodes, in conjunction with the amplifiers input configuration.
The feedback loops from the outputs of the amplifiers A and A generate virtual
I
V
shorts on the signal inputs. Exact duplications of the input currents are generated
for the analog processing circuitry.
VDD
II P
CURRE NT
V SS
S EN SOR
AI
INPUTS
V DD
II N
V SS
V DD
IVP
V OL TAGE
S EN SOR
V SS
INPUT
AV
D R-0 0 9 4 3
GND
3. Electrostatic Discharge (ESD) Protection
The SA9108F integrated circuit's inputs/outputs are protected against ESD .
4. Power Consumption
The overall power consumption rating of the SA9108F integrated circuit is less than
40mW having a 5V supply.
6/12
sames