English
Language : 

SA9105A Datasheet, PDF (6/12 Pages) Sames – THREE PHASE UNIDIRECTIONAL POWER/ENERGY METERING IC WITH PULSE OUTPUT
SA9105A
2. Analog Input Configuration
The current and voltage sensor inputs are illustrated below.
These inputs are protected against electrostatic discharge through clamping
diodes, in conjunction with the amplifiers input configuration.
The feedback loops from the outputs of the amplifiers A and A generate virtual
I
V
shorts on the signal inputs. Exact duplications of the input currents are generated
for the analog processing circuitry
VD D
IIP
CURRENT
V SS
SENSOR
AI
INPUTS
V DD
IIN
V SS
V DD
IVP
VOLTAGE
SENSOR
V SS
INPUT
AV
DR-00904
GND
3. Electrostatic Discharge (ESD) Protection
The SA9105A integrated circuit's inputs/outputs are protected against ESD according
to Mil-Std 883 method 3015. The SA9105A integrated circuit's resistance to
transients is also dependant upon the external protection components used.
4. Power Consumption
The overall power consumption rating of the SA9105A integrated circuit is less than
75mW with a 5V supply.
6/12
sames