ELECTRICAL CHARACTERISTICS
(VDD = 2.5V, VSS = -2.5V, over the temperature range -10°C to +70°C#, unless otherwise specified.)
Parameter
Symbol
Min
Typ
Max
Unit
Operating temp. Range
TO
Supply Voltage: Positive
VDD
Supply Voltage: Negative
VSS
Supply Current: Positive
IDD
Supply Current: Negative
ISS
Current Sensor Inputs (Differential)
Input Current Range
III
Voltage Sensor Input (Asymmetrical)
Input Current Range
IIV
Pin VREF
Ref. Current
-IR
Ref. Voltage
VR
Digital I/O
Pins RLOAD, TEST, SDA
VIH
Input High Voltage
Input Low Voltage
VIL
Pins MOP, MON, LED, SCL,
PH/DIR, PH1, PH2, PH3
Output High Voltage
VOH
Output Low Voltage
VOL
Pin SDA
Pull up current
-IIL
Pins TEST, RLOAD
Pull down current
IIH
-25
2.25
-2.75
15
15
+85
°C
2.75
V
-2.25
V
16
mA
16
mA
-25
+25
µA
-25
+25
µA
45
50
55
µA
1.1
1.3
V
VDD-1
VDD-1
24
48
V
VSS+1
V
V
VSS+1
V
54
µA
110
µA
#Extended Operating Temperature Range available on request.
Condition
Peak value
Peak value
With R = 24kW
connected to VSS
Reference to VSS
IOH = -2mA
IOL = 5mA
VI = VSS
VI = VDD
ABSOLUTE MAXIMUM RATINGS*
Parameter
Symbol
Min
Supply Voltage
Current on any pin
Storage Temperature
Operating Temperature
VDD -VSS
IPIN
TSTG
TO
-0.3
-150
-40
-40
Max
Unit
6.0
V
+150
mA
+125
°C
+85
°C
*Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress
rating only. Functional operation of the device at these or any other condition above those indicated in the operational sections of
this specification, is not implied. Exposure to Absolute Maximum Ratings for extended periods may affect device reliability.