English
Language : 

SA2002D Datasheet, PDF (2/10 Pages) Sames – Single Phase Kilowatt-hour Metering IC for Mechanical Display Applications
SA2002D
sames
ELECTRICAL CHARACTERISTICS
(VDD = 2.5V, VSS = -2.5V, over the temperature range -10°C to +70°C#, unless otherwise specified.)
Parameter
Symbol
Min
Typ
Max
Unit
Operating temp. Range
TO
Supply Voltage: Positive
VDD
Supply Voltage: Negative
VSS
Supply Current: Positive
IDD
Supply Current: Negative
ISS
Current Sensor Inputs (Differential)
-25
+85
°C
2.25
2.75
V
-2.75
-2.25
V
2.5
3.6
5
mA
2.5
3.6
5
mA
Input Current Range
II I
-25
Voltage Sensor Input (Asymmetrical)
Input Current Range
II V
-25
Pin VREF
+25
µA
+25
µA
Ref. Current
Ref. Voltage
-IR
45
50
55
µA
VR
1.1
1.3
V
Digital I/O
Pin R0, R1, R2, DIRI, CNF
Input High Voltage
Input Low Voltage
Pin MOP, MON, LED, DIRO
Output High Voltage
Output Low Voltage
VI H
VDD-1
VI L
VOH
VDD-1
VOL
V
VSS+1
V
V
VSS+1
V
#Extended Operating Temperature Range available on request.
Condition
Peak value
Peak value
With R = 24kW
connected to VSS
Reference to VSS
ABSOLUTE MAXIMUM RATINGS*
Parameter
Symbol
Min
Max
Unit
Supply Voltage
VDD -VSS
3.2
6.0
V
Current on any pin
IPI N
-150
+150
mA
Storage Temperature
TSTG
-40
+125
°C
Operating Temperature
TO
-25
+85
°C
*Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress
rating only. Functional operation of the device at these or any other condition above those indicated in the operational sections of
this specification, is not implied. Exposure to Absolute Maximum Ratings for extended periods may affect device reliability.
http://www.sames.co.za
23/10