English
Language : 

LSH14 Datasheet, PDF (1/2 Pages) saftbatteries – 3.6 V Primary lithium-thionyl chloride High power C-size spiral cell
Primary lithium battery
LSH 14
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
High power
C-size spiral cell
Benefits
q High voltage response, stable during
most of the lifetime of the application
q High drain/pulse capability
q Wide operating temperature range
(- 60°C/85°C)
q Easy integration in compact system
q Low self-discharge rate
(less than 3 % after 1 year of storage
at + 20°C)
Key features
q Stainless steel container
q Hermetic glass-to-metal sealing
q Built-in safety vent
q Finish with 5 A fuse
q Non-flammable electrolyte
q Underwriters Laboratories (UL)
Component Recognition
(File Number MH 12609)
q Compliant with IEC 60086-4
q Restricted for transport (Class 9)
Cell size references
UM2 – R14 – C
Electrical characteristics
(typical values relative to cells stored for one year or less at + 30°C max.)
Nominal capacity
(at 15 mA + 20°C 2.0 V cut-off. The capacity restored by the cell varies
according to current drain, temperature and cut-off)
5.8 Ah
Open circuit voltage (at + 20°C)
3.67 V
Nominal voltage
(at 1mA + 20°C)
3.6 V
Pulse capability: Typically up to 2000 mA
(2000 mA/0.1 second pulses, drained every 2 mn at + 20°C from
undischarged cells with 10 µA base current, yield voltage readings above
3.0 V. The readings may vary according to the pulse characteristics, the
temperature, and the cell's previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current
(to maintain cell heating within safe limits. Battery packs may imply lower
level of maximum current and may request specific thermal protection.
Consult Saft)
1300 mA
Storage
(recommended)
(for more severe conditions, consult Saft)
+ 30°C (+ 86°F) max
Operating temperature range
(Operation at extreme T may lead to reduced capacity and lower voltage
readings at the beginning of pulses. Consult Saft)
- 60°C/+ 85°C
(- 76°F/+ 185°F)
Main applications
q Radiocommunication and other
military applications
q Alarms and security systems
q Beacons and emergency location
transmitters
q GPS
q Metering systems
q Sonobuoys
q Automotive telematics
q Pipeline inspection
Physical characteristics
Diameter (max)
Height (max)
Typical weight
Li metal content
Available termination suffix
CN, CNR
3PF, 3 PF RP
CNA (AX)
FL
26.0 mm (1.02 in)
50.4 mm (1.98 in)
51 g (1.8 oz)
approx. 1.7 g
radial tabs
radial pins
axial leads
flying leads ...etc.
NATO stock number
6135 12 306 4125
June 2007