English
Language : 

LS33600 Datasheet, PDF (1/2 Pages) saftbatteries – 3.6 V Primary lithium-thionyl chloride High energy
Primary lithium battery
LS 33600
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
High energy
D-size bobbin cell
Benefits
l High voltage response, stable
during most of the lifetime of the
application
l Wide operating temperature
range (- 60°C/85°C)
l Easy integration in compact
system
l Low self-discharge rate
(less than 1 % after 1 year of
storage at + 20°C)
Key features
l Stainless steel container
l Hermetic glass-to-metal sealing
l Built-in safety vent
l Finish with or without flat
positive end
l Non-flammable electrolyte
l Compliant with IEC 60086-4
safety standard and
IEC 60079-11 intrinsic safety
standard
l Underwriters Laboratories (UL)
Component Recognition
(File Number MH 12609)
l Restricted for transport (Class 9)
Main applications
l Utility metering
l Automatic meter readers
l Buoys
l Measuring equipment
l Industrial applications
l Professional electronics
l Marine equipment
Optional upon request
l Low magnetic version
Cell size references
D
Electrical characteristics
(typical values relative to cells stored for one year or less at + 30°C max.)
Nominal capacity
17.0 Ah
(at 5 mA + 20°C 2.0 V cut-off. The capacity restored by the cell varies
according to current drain, temperature and cut-off)
Open circuit voltage (at + 20°C)
3.67 V
Nominal voltage
(at 0.7 mA + 20°C)
3.6 V
Nominal energy
61.2 Wh
Pulse capability: Typically up to 400 mA
(400 mA/0.1 second pulses, drained every 2 mn at + 20°C from undischarged cells with 10 µA
base current, yield voltage readings above 3.0 V. The readings may vary according to the pulse
characteristics, the temperature, and the cell’s previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current
(to maintain cell heating within safe limits. Battery packs may imply lower
level of maximum current and may request specific thermal protection.
Consult Saft)
250 mA
Storage
(recommended)
(for more severe conditions, consult Saft)
+ 30°C (+ 86°F) max
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult Saft)
- 60°C/+ 85°C
(- 76°F/+ 185°F)
Physical characteristics
Diameter (max)
Height (max)
Typical weight
Li metal content
Available termination suffix
CN, CNR
CNA (AX)
FL
33.4 mm (1.32 in)
60.2 or 61.6 mm
(2.37 in or 2.42 in)
depending on finish type
90 g (3.2 oz)
approx. 4.5 g
radial tabs
axial leads
flying leads... etc.
July 2010