English
Language : 

MSW150 Datasheet, PDF (1/2 Pages) RUBYCON CORPORATION – Resonant switchers, power factor correction and main converter
MSW150
*Resonant switchers, power factor correction and main converter
*Power factor correction up to 0.99, meeting IEC61000
-3-2(EN61000-3-2)
*85 to 264VAC universal input
*High efficiency up to 90%
*Low EMI, meeting FCC B, CISPR B
*Less then 0.3mA leakage
*Thin type below 1U
UL2601-1 Recognized
CSA22.2 No.601.1 Certified (cUL)
EN60601-1 (NEMKO Certified)
CE mark (LVD only)
*Madical equipment
* Safety systems
*Dental systems
*Control equipment
*Microprocessor systems
*Monitoring equipment
*Peak Loads (for Motor Drive, Lamp) *6
MSW150 SPECIFICATIONS
ITEM
MSW150-12
MSW150-15
MSW150-24
MSW150-36
1 Rated output DC voltage
12 V
15V
24 V
36V
2 Rated output DC current (Peak *6)
12.5 A (25A)
10.0A(20.0A)
6.3 A (12.5A)
4.2 A (8.3A)
3 Maximum output power (Peak *6)
150.0W(300.0W) 150.0W(300.0W) 151.2W(300.0W) 151.2W(298.8W)
4 Adjustable voltage range
*1 11.7 ~ 12.6V
14.7 ~ 15.8V
23.5 ~ 25.2V
35.3 ~ 37.7V
5 Efficiency (120/230VAC, TYP)
*1 85% / 86%
86% / 87%
87% / 88%
88% / 89%
6 Maximum ripple noise
80mVpp
100mVpp
150mVpp
200mVpp
7 Over current protection
*3 25.5A ~
20.5A ~
13A ~
8.5A ~
8 Over voltage protection
*4 13.8V ~
17.3V ~
27.6V ~
40V ~
9 Input voltage range
85V ~ 264V
10 Input frequency range
47Hz ~ 63Hz
11 Input current
*1 1.7A (100VAC), 0.8A(230VAC)
12 Power factor
*1 0.99TYP (100VAC), 0.95TYP (230VAC)
13 Inrush current
*2 20Apk MAX (120VAC), 40Apk MAX (240VAC)
14 Hold-up time
*5 20msMIN
Notes
*1 When maximum output is worked
*2 When cold start works with rated voltage at 25ºC ambient temperature
*3 Recovers automatically
*4 Recovers on input again
*5 When maximum output is worked, after last AC line peak
*6 (Peak) : Peak Loads for 10 seconds or less are acceptable. Input voltage range AC120V~AC264V only.
Specifications subject to change without notice.(2004.9)