English
Language : 

3R2002RDW Datasheet, PDF (1/3 Pages) RUBYCON CORPORATION – Resonant switchers, power factor correction and main converter
RDW SERIES
RDW 100
RDW 150
FEATURES
* Resonant switchers, power factor correction and main
converter
* Power factor correction up to 0.99, meeting IEC61000
-3-2(EN61000-3-2)
* 85 to 264VAC universal input
* High efficiency up to 85%
* Low EMI, meeting FCC B, CISPR B
SAFETY STANDARDS
UL1950 Recognized
CSA22.2 No.950 Certified (cUL)
EN60950 (TUV Certified)
CE mark (LVD only)
APPLICATIONS
*Data/information processing equipment
*FA control equipment
*Measuring, inspection and testing equipment
*Communication equipment
*Optical equipment
RDW SERIES GENERAL SPECIFICATIONS
ITEM
1 Input voltage range
2 Input frequency range
3 Operating temperature
4 Operating humidity
5 Storage temperature
6 Storage humidity
7 Cooling
8 Electric strength voltages
9 Insulation resistance
10 Leakage current
11 Vibration
12 Shock
13 Safety standards
14 Conduction noise
15 Harmonic distortion
16 Mains surge
85V ~ 264VAC
47Hz ~ 63Hz
-10 ~ 60oC (Refer to Output derating)
30 ~ 90%RH (Non condensing)
-30 ~ 85oC
10~95%RH (Non condensing)
Convection or forced air cooling (Refer to Output derating)
Input - Output 3000VAC 1 minute , Input - FG 1500VAC 1 minute , Output - FG 500VAC 1 minute
100MΩ MIN DC500V 25oC 70%RH Input - Output, Input - FG, Output - FG
0.5mA MAX (240VAC, 50Hz)
10 ~ 55Hz 2G (3 directions each 1 hour)
20 ms 20G (3 directions each 3 times)
UL1950, CSA950(cUL), EN60950(TUV) Approvals
Meeting FCC Class B, EN55022 Class B, VCCI Class B
Meeting EN61000-3-2
Meeting EN61000-4-5 Level 3 / 4KV(CM), 2KV(DM)