English
Language : 

PBW30F Datasheet, PDF (5/6 Pages) List of Unclassifed Manufacturers – AC-DC Power Supplies Enclosed type
AC-DC Power Supplies Enclosed type
PBW50F
Ordering information
PB W 50 F -O -O
1
2
3
4
5
6
PBA/PBW
R
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
1Series name
2Dual output
3Output wattage
4Universal input
5Output voltage
6Optional *9
C :with Coating
G :Low leakage current
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
R :with Remote ON/OFF
N :with Cover
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBW50F-5
*6 30
VOLTAGE[V] *8 t5 ( +10 )
CURRENT1[A] 3.0
CURRENT2[A]*6 4.0
PBW50F-12
50.4
t12 ( +24 )
2.1
2.7
PBW50F-15
51
t15 ( +30 )
1.7
2.4
SPECIFICATIONS
MODEL
PBW50F-5
PBW50F-12
PBW50F-15
VOLTAGE[V]
CURRENT[A]
AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3)
ACIN 100V 0.45typ (CURRENT1)
0.70typ (CURRENT1)
ACIN 200V 0.30typ (CURRENT1)
0.40typ (CURRENT1)
FREQUENCY[Hz]
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
ACIN 100V 76typ (CURRENT1)
ACIN 200V 77typ (CURRENT1)
81typ (CURRENT1)
83typ (CURRENT1)
81typ (CURRENT1)
83typ (CURRENT1)
POWER FACTOR(Io=100%)
ACIN 100V
ACIN 200V
0.98typ
0.87typ
0.99typ
0.93typ
INRUSH CURRENT[A]
ACIN 100V
ACIN 200V
15typ (CURRENT1) (At cold start)
30typ (CURRENT1) (At cold start)
LEAKAGE CURRENT[mA]
0.40/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
t5
/ ( +10V reference number ) t12
/ ( +24V reference number ) t15
/ ( +30V reference number )
CURRENT1[A]
3.0
/ 3.0
2.1
/ 2.1
1.7
/ 1.7
CURRENT2[A]
*6 4.0
/-
2.7
/-
2.4
/-
LINE REGULATION[mV]
20max
/ 36max
48max
/ 96max
60max
/ 96max
LOAD REGULATION 1[mV] *4 250max
/ 100max
600max
/ 150max
600max
/ 150max
LOAD REGULATION 2[mV] *5 500max
/-
750max
/-
750max
/-
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C*1 140max
/ 240max
/ 320max
120max
160max
/ 240max
/ 320max
120max
160max
/ 240max
/ 320max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1
-10 - 0C*1
120max
160max
/ 300max
/ 360max
150max
180max
/ 300max
/ 360max
150max
180max
/ 300max
/ 360max
TEMPERATURE REGULATION[mV]
0 to +50C
-10 to +50C
50max
60max
120max
150max
150max
180max
DRIFT[mV]
*2 20max
48max
60max
START-UP TIME[ms]
350typ(ACIN 100V, Io=100%)
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)
OUTPUT VOLTAGE SETTING[V] 4.99 - 5.30 (+V and -V CURRENT1)
11.5 - 12.5 (+V and -V CURRENT1)
14.4 - 15.6 (+V and -V CURRENT1)
OVERCURRENT PROTECTION
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
Works over 105% of rated current and recovers automatically
6.90 - 10.0
16.8 - 24.0
LED (Green)
Optional (Required external power source)
20.0 - 29.0
INPUT-OUTPUT -RC
*7 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
ISOLATION INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
OUTPUT-RC-FG
*7 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
NOISE
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
REGULATIONS HARMONIC ATTENUATOR
Complies with IEC61000-3-2 *10
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
31X82X120mm [1.22X3.23X4.72 inches] (without terminal block) (WXHXD) / 280g max (without cover)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise
meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C.
*3 Derating is required.
*4 Figures for 0 to rated current 1.The current not measured
side is fixed.
*5 Figures for 0 to rated current 2.The current not measured
side is fixed.
*6 The sum of +power -power must be less than output power.
*7 RC is applied to remote ON/OFF option. RC is isolated with
input/output and FG.
*8 t5,t12,t15 can be used as +10,+24 and +30.
*9 Please contact us about safety approvals for the model with
option.
*10 Please contact us about class C.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
PBA/PBW-30