English
Language : 

LFA30F Datasheet, PDF (5/18 Pages) RSG Electronic Components GmbH – AC-DC Power Supplies Open Frame/ Enclosed type
AC-DC Power Supplies Open Frame/ Enclosed type
LFA30F
0SEFSJOHJOGPSNBUJPO
LF A 30 F - ˘ - ˘
1
2
3
4
5
6
LFA
Recommended EMI/EMC Filter
NAC-04-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
to connect with several devices.
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
C : with Coating
G : Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y: with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA30F-3R3-Y
19.8
3.3V 6A
LFA30F-5
30.0
5V 6A
LFA30F-12
30.0
12V 2.5A
LFA30F-15
30.0
15V 2A
LFA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
LFA30F-3R3-Y
LFA30F-5
LFA30F-12
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *3
LFA30F-15
LFA30F-24
CURRENT[A]
ACIN 100V 0.50typ (Io=100%) 0.65typ (Io=100%)
ACIN 200V 0.30typ (Io=100%) 0.35typ (Io=100%)
FREQUENCY[Hz]
50 / 60 (47 - 440)
INPUT
EFFICIENCY[%]
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
73typ
76typ
75typ
79typ
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
79typ
81typ
81typ
83typ
82typ
84typ
LEAKAGE CURRENT[mA] 0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
VOLTAGE[V]
3.3
5
12
15
24
CURRENT[A]
6.0
6.0
2.5
2.0
1.3
LINE REGULATION[mV] *5 20max
20max
48max
60max
96max
OUTPUT
LOAD REGULATION[mV] *5 40max
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C *1 140max
0 to +50C*1 120max
RIPPLE NOISE[mVp-p] -10 - 0C *1 160max
0 to +50C 50max
TEMPERATURE REGULATION[mV] -10 to +50C 60max
40max
80max
140max
120max
160max
50max
60max
100max
120max
160max
150max
180max
120max
150max
120max
120max
160max
150max
180max
150max
180max
150max
120max
160max
150max
180max
240max
290max
DRIFT[mV]
*2 20max
20max
48max
60max
96max
START-UP TIME[ms]
150typ (ACIN 100V, Io=100%)
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 to 3.63
Fixed ( lYz option is available for adjusting output voltage between ±10%)
OUTPUT VOLTAGE SETTING[V] 3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
4.00 to 5.25
Not provided
Not provided
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
REMOTE ON/OFF
INPUT-OUTPUT
ISOLATION INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max *3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
HARMONIC ATTENUATOR
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2 (Class A) *6 (Not built-in to active filter) *4
50X26.5X105mm [1.97X1.04X4.13 inches] (WXHXD) / 130g max (without chassis and cover)
Convection (Refer to Instruction Manual 3.1 and 3.2) *3
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm
from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at
25C, with the input voltage held constant at the rated input/output.
*3 Derating is required.
LFA-6
*4 When two or more units are operating it may not comply with the IEC61000-3-2.
Please contact us for details.
*5 Please contact us about dynamic load and input response.
*6 Please contact us about another class.
* To meet the specifications. Do not operate over-loaded condition.
* Parallel operation is not possible.
* Derating is required when operated with chassis and cover.
* Sound noise may be generated by power supply in case of pulse load.