English
Language : 

LFA150F Datasheet, PDF (3/18 Pages) RSG Electronic Components GmbH – AC-DC Power Supplies Open Frame/ Enclosed type
AC-DC Power Supplies Open Frame/ Enclosed type
LFA15F
0SEFSJOHJOGPSNBUJPO
LF A 15 F - ˘ - ˘
1
2
3
4
5
6
LFA
Recommended EMI/EMC Filter
NAC-04-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
to connect with several devices.
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
C : with Coating
G : Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y: with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA15F-3R3-Y
9.9
3.3V 3A
LFA15F-5
15
5V 3A
LFA15F-12
15.6
12V 1.3A
LFA15F-15
15
15V 1A
LFA15F-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
LFA15F-3R3-Y
LFA15F-5
LFA15F-12
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2) *3
LFA15F-15
LFA15F-24
CURRENT[A]
ACIN 100V 0.24typ (Io=100%) 0.35typ (Io=100%)
ACIN 200V 0.15typ (Io=100%) 0.20typ (Io=100%)
FREQUENCY[Hz]
50 / 60 (47 - 440)
INPUT
EFFICIENCY[%]
INRUSH CURRENT[A]
ACIN 100V
ACIN 200V
ACIN 100V
ACIN 200V
68.0typ
73.0typ
69.0typ
76.0typ
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
76.0typ
78.5typ
77.0typ
80.0typ
78.0typ
81.5typ
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
VOLTAGE[V]
3.3
5
12
15
24
CURRENT[A]
3.0
3.0
1.3
1.0
0.7
LINE REGULATION[mV] *5 20max
20max
48max
60max
96max
OUTPUT
LOAD REGULATION[mV] *5 40max
RIPPLE[mVp-p]
0 to +50C 80max
*1 -10 - 0C 140max
Io=0 - 35% 190max
0 to +50C 120max
RIPPLE NOISE[mVp-p]
*1
-10 - 0C 160max
Io=0 - 35% 240max
0 to +50C 50max
TEMPERATURE REGULATION[mV] -10 to +50C 60max
40max
80max
140max
160max
120max
160max
240max
50max
60max
100max
120max
160max
240max
150max
180max
300max
120max
150max
120max
120max
160max
240max
150max
180max
300max
150max
180max
150max
120max
160max
280max
150max
180max
320max
240max
290max
DRIFT[mV]
START-UP TIME[ms]
*2 20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)ɹ*Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed ( lYz option is available for adjusting output voltage between ±10%)
OUTPUT VOLTAGE SETTING[V] 3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION 4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
CIRCUIT AND OPERATING INDICATION
Not provided
OTHERS
REMOTE SENSING
Not provided
ISOLATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
ENVIRONMENT
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max *3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
OTHERS
AGENCY APPROVALS
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2 (Class A) *6 (Not built-in to active filter) *4
50X22X87.5mm [1.97X0.87X3.44 inches] (WXHXD) / 80g max (without chassis and cover)
Convection (Refer to Instruction Manual 3.1 and 3.2) *3
*1 This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
A circuit reducing standby power is built in this unit.
Therefore, the internal switch element is intermittent
operated, and the Ripple/Ripple Noise specification in load
LFA-4
factor Io=0-35% is different.
Please contact us for details.
Please refer to the Instruction Manual 1.7.
*5 Please contact us about dynamic load and input response.
*2 Drift is the change in DC output for an eight hour period after *6 Please contact us about another class.
a half-hour warm-up at 25C, with the input voltage held
constant at the rated input/output.
* To meet the specifications. Do not operate over-loaded condition.
* Parallel operation is not possible.
*3 Derating is required.
*
*4 When two or more units are operating it may not comply with *
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse
the IEC61000-3-2.
load.