English
Language : 

TUNS50 Datasheet, PDF (1/4 Pages) RSG Electronic Components GmbH – AC-DC Power Supplies Power Module type
AC-DC Power Supplies Power Module type
TUNS50
Ordering information
TUN S 50 F 05 -O
1
2
3
4
5
6
*Providing heat sink
as option
1Series name
2Single output
3Output wattage
4Universal Input
5Output voltage
6Optional
T : with Mounting hole
(f3.4 thru)
TU
*Avoid short circuit between +BC and -BC. It may cause the failure of inside components.
*Keep TRM open, if output voltage adjustment is not necessary.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
TUNS50F05
50.0
5V 10A
TUNS50F12
50.4
12V 4.2A
TUNS50F24
50.4
24V 2.1A
SPECIFICATIONS
MODEL
VOLTAGE[V]
TUNS50F05
TUNS50F12
AC85 - 264 1f (Please refer to the instruction manual, 6.5 Derating)
TUNS50F24
CURRENT[A]
ACIN 100V 0.67typ (Io=100%)
ACIN 200V 0.35typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
ACIN 100V 79typ
ACIN 200V 81typ
83typ
84typ
84typ
86typ
ACIN 100V 0.95typ
POWER FACTOR (Io=100%)
ACIN 200V 0.90typ
INRUSH CURRENT
Limited by external components (Thermistor)
LEAKAGE CURRENT[mA] 0.75 max (60Hz, According to IEC60950-1)
VOLTAGE[V]
5
12
24
CURRENT[A]
10
4.2
2.1
LINE REGULATION[mV]
10max
24max
48max
LOAD REGULATION[mV] 10max
0 to +100C*1 80max
RIPPLE[mVp-p]
-40 to 0C*1 120max
24max
120max
150max
48max
120max
150max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to 15% Load*1 200max
0 to +100C*1 120max
-40 to 0C*1 200max
280max
150max
200max
380max
150max
250max
0 to 15% Load*1 280max
0 to +65C 50max
TEMPERATURE REGULATION[mV] -40 to +100C 100max
360max
120max
240max
460max
240max
480max
DRIFT[mV]
*2 20max
40max
90max
Fixed (TRM pin open), adjustable by external resistor or external signal
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 - 6.00
10.80 - 13.20
21.60 - 26.40
OUTPUT VOLTAGE SETTING[V] 4.97 - 5.13
11.91 - 12.29
23.62 - 24.38
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
ISOLATION INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
Works over 105% of rating and recovers automatically
6.30 - 7.00
13.90 - 16.35
27.60 - 32.40
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AND
AGENCY APPROVALS
NOISE REGULATIONS HARMONIC ATTENUATOR
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178
Complies with IEC61000-3-2 (Class A) *3
58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 80g max
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to instruction manual for measuring method of electric characteristics.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Please contact us about another class.
TU-2