TP-100 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 100W Triple Output with PFC Function
RSG■
ELECTRONIC COMPONENTS
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
100W Triple Output with PFC Function
TP-100 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.94
Protections:Short circuit/Over load/Over voltage
Free air cooling convection
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
TP-100A
TP-100B
TP-100C
TP-100D
OUTPUT NUMBER
CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V 5V
15V
-15V 5V
24V
12V
RATED CURRENT
10A
4A
0.6A 10A
4A
0.6A 10A
3A
0.6A 10A
2A
0.6A
CURRENT RANGE
3 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0.4 ~ 5A 0 ~ 1A 3 ~ 15A 0.4 ~ 4A 0 ~ 1A 3 ~ 15A 0.4 ~ 3A 0 ~ 1A
RATED POWER (max.)
101W
105.2W
104W
105.2W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 3.0% 7.0% 6.0% 3.0% 6.0% 6.0% 3.0% +10,-6% 6.0% 3.0% 8.0% 6.0%
LINE REGULATION
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LOAD REGULATION
3.0% 6.0% 4.0% 3.0% 6.0% 4.0% 3.0% 6.0% 4.0% 3.0% 6.0% 4.0%
SETUP, RISE TIME
800ms, 60ms/230VAC 800ms, 60ms/115VAC at full load
HOLD TIME (Typ.)
24ms/230VAC 24ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
127 ~ 370VDC
POWER FACTOR (Typ.)
PF>0.94/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
75%
78%
77%
78%
AC CURRENT (Typ.)
1.5A/115VAC 0.75A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230V
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
PROTECTION OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V on +5V
Protection type : Shut down o/p voltage, re-power on to recover
95 5 (TSW1)
OVER TEMPERATURE(OPTION) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
170.1K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
199*99*50mm (L*W*H)
PACKING
0.83Kg; 20pcs/17.6Kg/1.28CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:TP-100-SPEC 2006-08-22