English
Language : 

SCP-600 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 500~600W Parallel Type With PFC Function
RSG■
ELECTRONIC COMPONENTS
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
500~600W Parallel Type With PFC Function
SCP-600 series
Features :
AC 180~260VAC input
PF> 0.98@ 230VAC
Protections: Short circuit/ Overload/ Over voltage/ Over temperature
Built in remote sense function
Built-in remote ON-OFF control
Power good signal
With parallel function(N+1)
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
3 years warranty
SPECIFICATION
ORDER NO.
SCP-600-05 SCP-600-09 SCP-600-12 SCP-600-15 SCP-600-18 SCP-600-24 SCP-600-36 SCP-600-48 SCP-600-60
SAFETY MODEL NO.
600S-P005 600S-P009 600S-P012 600S-P015 600S-P018 600S-P024 600S-P036 600S-P048 600S-P060
DC VOLTAGE
5V
9V
12V
15V
18V
24V
36V
48V
60V
RATED CURRENT
100A
66A
50A
40A
33.3A
25A
16.6A
12A
10A
CURRENT RANGE
0 ~ 100A 0 ~ 66A
0 ~ 50A
0 ~ 40A
0 ~ 33.3A 0 ~ 25A
0 ~ 16.6A 0 ~ 12A
0 ~ 10A
OUTPUT
RATED POWER
500W
594W
600W
600W
600W
600W
500W
576W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p 360mVp-p 480mVp-p
VOLTAGE ADJ. RANGE
3.0% Typical adjustment by potentiometer 20%~100% adjustment by 1~5VDC external control
VOLTAGE TOLERANCE Note.3 1.5%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
600W
500mVp-p
1.0%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD TIME 500ms, 250ms, 16ms at full load
VOLTAGE RANGE
180 ~ 260VAC 260 ~ 370VDC see the derating curve
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
>0.98 / 230VAC
INPUT
EFFICIENCY (Typ.)
80%
82%
84%
85%
86%
89%
89%
90%
90%
AC CURRENT
5.0A / 230VAC
INRUSH CURRENT (max.) 60A / 230VAC
LEAKAGE CURRENT (max.) 3.5mA / 240VAC
OVER LOAD
105 ~ 115% rated output power
Note. 4
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
110 ~ 135% Follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-20 ~ +65 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 10 ~ 95% RH
TEMP. COEFFICIENT
0.04% / (0 ~ 50 )
VIBRATION
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950, TUV EN60950-1 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC
EMC
(Note. 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) class A
HARMONIC CURRENT
Compliance to EN61000-3-2,3
EMS IMMUNITY
POWER GOOD SIGNAL
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
Open collector of NPN transistor
SPECIAL FUNCTION
DC Voltage Adj., remote sensing, remote control, parallel operation(refer to control terminal instruction manual)
COOLING
OTHERS
MTBF
By fan, >20% load or >50 fan on
74.9K hrs min. MIL-HDBK-217F(25 )
DIMENSION
290*120*68mm (L*W*H)
PACKING
2.3kg ; 8pcs / 20kg / CARTON
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name: SCP-600-SPEC 2006-03-28