English
Language : 

RS-150 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 150W Single Output Switching Power Supply
RSG■
ELECTRONIC COMPONENTS
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
150W Single Output Switching Power Supply
RS-150 series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
High realibility
SPECIFICATION
MODEL
RS-150-3.3
RS-150-5
RS-150-12
RS-150-15
RS-150-24
RS-150-48
OUTPUT
INPUT
DC VOLTAGE
3.3V
5V
12V
15V
24V
RATED CURRENT
30A
26A
12.5A
10A
6.5A
CURRENT RANGE
0 ~ 30A
0 ~ 26A
0 ~ 12.5A
0 ~ 10A
0 ~ 6.5A
RATED POWER
99W
130W
150W
150W
156W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
120mVp-p
120mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
3.2V ~ 3.5V
4.75 ~ 5.5V
11.4 ~ 13.2V
14.25 ~ 16.5V
22.8 ~ 26.4V
VOLTAGE TOLERANCE Note.3 3.0%
2.0%
1.0%
1.0%
1.0%
LINE REGULATION Note.4 0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION Note.5 2.0%
1.0%
0.5%
0.5%
0.5%
SETUP, RISE, HOLD TIME 800ms, 20ms, 20ms/230VAC 1200ms, 30ms, 10ms/115VAC at full load
VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(300VAC peak 5sec. No damage)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
75%
78%
83%
84%
86%
AC CURRENT
3A/115VAC 2A/230VAC
INRUSH CURRENT(max.) COLD START 50A/230VAC
48V
3.3A
0 ~ 3.3A
158.4W
200mVp-p
45.6 ~ 52.8V
1.0%
0.5%
0.5%
87%
LEAKAGE CURRENT
<2mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
27.6 ~ 32.4V
55.2 ~ 64.8V
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 6)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
MTBF
244KHrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
199*98*38mm (L*W*H)
NOTE
PACKING
0.7Kg; 20pcs/14Kg/0.72CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:RS-150-SPEC 2004-03-25