100W Quad Output with PFC Function
QP-100 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections:Short circuit/Over load/Over voltage
Free air cooling convection
CH4: Polarity is selectable
Fixed switching frequency at 100KHz
3 years warranty
..
SPECIFICATION
MODEL
QP-100-3A
QP-100-3B
QP-100-3C
OUTPUT NUMBER
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
DC VOLTAGE
5V
3.3V 12V
-5V
5V
3.3V 12V
-12V 5V
3.3V 15V
-15V
RATED CURRENT
8A
8A
2.5A 0.6A 8A
8A
2.2A 0.6A 8A
8A
1.7A 0.6A
CURRENT RANGE
2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A 2 ~ 10A 0 ~ 10A 0.3 ~ 3A 0 ~ 1A 2 ~ 10A 0 ~ 10A 0.3 ~ 2A 0 ~ 1A
OUTPUT
RATED POWER (max.)
99.4W
100W
100.9W
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V
VOLTAGE TOLERANCE Note.3 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% 6.0% 5.0% 3.0% 3.0% +8,-6% 5.0%
LINE REGULATION
1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0% 1.0% 1.0% 2.0% 1.0%
LOAD REGULATION
2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0% 2.0% 2.0% 6.0% 2.0%
SETUP, RISE TIME
800ms, 50ms/230VAC 800ms, 50ms/115VAC at full load
HOLD TIME (Typ.)
24ms/230VAC 24ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.98/115VAC at full load
INPUT
EFFICIENCY (Typ.)
74%
74%
75%
AC CURRENT (Typ.)
1.5A/115VAC 0.75A/230VAC
INRUSH CURRENT (Typ.) COLD START 40A/230V
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
95 5 (TSW1)
OVER TEMPERATURE(OPTION) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0~50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
OTHERS
NOTE
MTBF
139.9K hrs min. MIL-HDBK-217F (25 )
DIMENSION
199*99*50mm (L*W*H)
PACKING
0.87Kg; 20pcs/18.4Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-100-SPEC 2006-08-22