120W Quad Output Switching Power Supply
Q-120 series
Features :
AC input range selected by switch
Protections:Short circuit/Over load/Over voltage
100% full load burn-in test
Fixed switching frequency at 25KHz
2 years warranty
SPECIFICATION
MODEL
Q-120B
Q-120C
Q-120D
OUTPUT NUMBER
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
DC VOLTAGE
5V
12V
-5V
-12V 5V
15V
-5V
-15V 5V
12V
24V
-12V
RATED CURRENT
11A
4A
1A
1A
10A
3.5A 1A
1A
8A
2A
2A
1A
CURRENT RANGE
2 ~ 12A 0.5 ~ 5A 0.2 ~ 1A 0.2 ~ 1A 2 ~ 12A 0.5 ~ 5A 0.2 ~ 1A 0.2 ~ 1A 2 ~ 12A 0.2 ~ 5A 0.2 ~ 2A 0.2 ~ 1A
RATED POWER
120W
122.5W
124W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 120mVp-p 80mVp-p 150mVp-p 80mVp-p 150mVp-p 80mVp-p 120mVp-p 180mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0% 6.0% 6.0% 6.0% 2.0% +10,-5% 6.0% +10,-5% 2.0% 6.0% 6.0% 6.0%
LINE REGULATION
0.5% 1.0% 1.0% 1.0% 0.5% 1.0% 1.0% 1.0% 0.5% 1.0% 1.0% 1.0%
LOAD REGULATION
0.5% 5.0% 5.0% 5.0% 0.5% 6.0% 5.0% 6.0% 0.5% 5.0% 5.0% 5.0%
SETUP, RISE, HOLD TIME 200ms, 50ms, 20ms at full load
VOLTAGE RANGE
88 ~ 132VAC/176 ~ 264VAC selected by switch 240 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
77%
76%
80%
AC CURRENT
2.8A/115VAC 1.6A/230VAC
INRUSH CURRENT (max.) COLD START 35A
LEAKAGE CURRENT
<3.5mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
105 ~ 135% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
CH1:5.75 ~ 6.75VDC
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
EMC
(Note 4)
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
OTHERS
NOTE
MTBF
261.4K hrs min. MIL-HDBK-217F (25 )
DIMENSION
199*110*50mm (L*W*H)
PACKING
0.86Kg; 16pcs/14.7Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:Q-120-SPEC 2004-11-30