English
Language : 

PFC200_14 Datasheet, PDF (1/2 Pages) RSG Electronic Components GmbH – 200 WATT POWER FACTOR CORRECTED SUPPLIES
200 WATT POWER FACTOR CORRECTED SUPPLIES
DESCRIPTION
The PFC200 series comprises single and multiple output
models for 200 watts of continuous output power. All models
have a power factor better than 0.95, and have the same
mechanical dimensions and output pinning as their
corresponding PU200 series models. All auxiliary outputs
are with magnetic amplifier to keep regulation. The units are
constructed on a printed circuit board with a U-bracket for
mechanical support and heat sinking. Both “B” and “C”
versions are with UL, CSA and TÜV approvals.
PFC200 SERIES
( LV D )
RoHS
F E AT U R E S
‧ Power factor 0.98 typical
‧ 90 VAC to 264 VAC universal input
‧ In compliance with EN 55024, EN 61000-3-2 and
EN 61000-3-3
‧ Overvoltage protection
‧ Short-circuit protection
‧ Power Fail Detect( PFD) signal
‧ 100﹪ burn-in at full rated load
‧ Remote sense on single output models
‧ Compliant with RoHS requirements
Safety Standard Approvals:
UL 60950-1, CSA C22.2 NO. 60950-1
File No. E137410
TÜV EN60950-1
Certificate No. R9955628
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
Touch current:
90 to 264VAC
47 to 63Hz
3.6A( rms) for 115VAC
1.8A( rms) for 230VAC
0.4mA max. @115VAC, 60Hz
0.8mA max. @230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/current: See rating chart
Total output power:
200 watts maximum
Ripple and noise:
2﹪peak to peak maximum
Overvoltage protection: Provided on output #1 only;
set at 112-132﹪ of its nominal
output voltage
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04/℃ maximum
Transient response:
Maximum excursion of 4﹪or
better on all models, recovering
to 1﹪of final value within 500us
after a 25﹪step load change
PFD signal:
TTL logic high for normal
operation and TTL logic low
upon loss of input power. This
signal appears at least 1ms prior
to +5V output dropping 5%
below its nominal value. This
signal also provides a minimum
delay of 100ms after +5V is
within regulation.
1-27
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Cooling:
0℃ to +70℃
-40℃ to +85℃
5% to 95% non-condensing
Derate from 100% at +50℃
linearly to 50% at +70℃
25 CFM forced air, provided on
“C” version, to be provided for
“B” version by user
GENERAL SPECIFICATIONS
Switching frequency: 94KHz ±10KHz
Power factor:
0.98 typical
Efficiency:
70﹪minimum on all models
Hold-up time:
12 msec minimum at 110VAC
Line regulation:
±0.5﹪maximum at full load
Inrush current:
20 amps @ 115VAC or 40 amps
@ 230VAC, at 25℃ cold start
Withstand voltage: 3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
300,000 hours at full load at
25℃ ambient , calculated per
MIL-HDBK-217F
EMC Performance (EN55024)
EN55022:
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ± 8KV air and ± 4KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ± 1KV
EN61000-4-5:
Surge, ± 1KV diff., ± 2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
E N 6 1 0 0 0 - 4 - 11 :
Voltage dips, 30﹪ reduction for
500ms and >95﹪reduction for 10ms