45W Dual Output Switching Power Supply
PD-45 series
Features :
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
PD-45A
PD-45B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
5V
12V
5V
24V
RATED CURRENT
3.2A
2A
3.2A
1.2A
CURRENT RANGE
0.4 ~ 5A
0.2 ~ 2.5A
0.4 ~ 5A
0.2 ~ 1.8A
RATED POWER
40W
44.8W
OUTPUT POWER (max.)
Rated output power for convection; 52W with 18CFM min. Forced air
OUTPUT RIPPLE & NOISE (max.) Note.2 50mVp-p
120mVp-p
50mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 4.0%
7.0%
LINE REGULATION
1.0%
2.0%
CH1:4.75 ~ 5.5V
4.0%
7.0%
1.0%
2.0%
LOAD REGULATION
3.0%
4.0%
3.0%
4.0%
SETUP, RISE TIME
800ms, 20ms at full load
HOLD UP TIME (Typ.)
60ms at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~370VDC
FREQUENCY RANGE
47 ~ 440Hz
INPUT
EFFICIENCY(Typ.)
77%
78%
AC CURRENT (Typ.)
1A/115VAC 0.7A/230VAC
INRUSH CURRENT (Typ.) COLD START 15A/115VAC 30A/230VAC
LEAKAGE CURRENT
<0.75mA
OVERLOAD
PROTECTION
OVER VOLTAGE
53 ~ 75W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
5.75 ~ 6.75VDC on CH1
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.04%/ (0 ~ 50 ) on +5V output
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
SAFETY STANDARDS
UL60950, TUV EN60950-1 Approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
288.1K hrs min. MIL-HDBK-217F (25 )
DIMENSION
127*76*28mm (L*W*H)
PACKING
0.2Kg; 72pcs/16Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:PD-45-SPEC 2006-12-19