English
Language : 

PBW15F Datasheet, PDF (1/6 Pages) RSG Electronic Components GmbH – AC-DC Power Supplies Enclosed type
AC-DC Power Supplies Enclosed type
Ordering information
PBW15F
PB W 15 F -O -O
1
2
3
4
5
6
PBA/PBW
R
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
1Series name
2Dual output
3Output wattage
4Universal input
5Output voltage
6Optional *10
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBW15F-12
*5 16.8
VOLTAGE[V] *6 t12 ( +24 )
CURRENT1[A] 0.7
CURRENT2[A]*5 1.4
PBW15F-15
15.0
t15 ( +30 )
0.5
1.0
SPECIFICATIONS
MODEL
PBW15F-12
PBW15F-15
VOLTAGE[V]
CURRENT[A]
AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *8)
ACIN 100V 0.40typ (CURRENT1)
ACIN 200V 0.20typ (CURRENT1)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
INPUT
EFFICIENCY[%]
ACIN 100V 74typ (CURRENT1)
ACIN 200V 77typ (CURRENT1)
78typ (CURRENT1)
80typ (CURRENT1)
ACIN 100V 15typ (CURRENT1) (At cold start)
INRUSH CURRENT[A] ACIN 200V 30typ (CURRENT1) (At cold start)
LEAKAGE CURRENT[mA]
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
t12
/ ( +24V reference number ) t15
/ ( +30V reference number )
CURRENT1[A]
0.7
/ 0.7
0.5
/ 0.5
CURRENT2[A]
*5 1.4
LINE REGULATION[mV]
LOAD REGULATION 1[mV]
LOAD REGULATION 2[mV]
**191 60max
**131 600max
**141 750max
RIPPLE[mVp-p]
0 to +50C*1 120max
-10 - 0C*1 160max
/-
/ 96max
/ 150max
/-
/ 240max
/ 320max
1.0
60max
600max
750max
120max
160max
/-
/ 96max
/ 150max
/-
/ 240max
/ 320max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1
-10 - 0C*1
150max
180max
/ 300max
/ 360max
150max
180max
/ 300max
/ 360max
TEMPERATURE REGULATION[mV] 0 to +50C 120max
-10 to +50C 150max
150max
180max
DRIFT[mV]
*2 48max
60max
START-UP TIME[ms]
HOLD-UP TIME[ms]
200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 9.60 - 13.2 (+V and -V are simultaneously adjusted)
13.2 - 16.5 (+V and -V are simultaneously adjusted)
OUTPUT VOLTAGE SETTING[V] 11.5 - 12.5 (+V and -V CURRENT1)
14.4 - 15.6 (+V and -V CURRENT1)
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND
OTHERS
OPERATING INDICATION
REMOTE ON/OFF
Works over 105% of rated current and recovers automatically
16.8 - 24.0
LED (Green)
None
20.0 - 29.0
INPUT-OUTPUT
ISOLATION INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input)
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Not built-in to active filter *7) *12
31X78X85mm [1.22X3.07X3.35 inches] (without terminal block) (WXHXD) / 200g max (without cover)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise
meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C.
*3 Figures for 0 to rated current 1.The current not measured
side is fixed.
*4 Figures for 0 to rated current 2.The current not measured
side is fixed.
*5 The sum of +power -power must be less than output power.
*6 t12,t15 can be used as +24 and +30.
*7 When two or more units are used,they may not comply with
the harmonic attenuator. Please contact us for details.
*8 Derating is required.
*9 Figures to rated current 1.
*10 Please contact us about safety approvals for the model with
option.
*11 Please contact us about dynamic load and input response.
*12 Please contact us about class C.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
PBA/PBW-26