English
Language : 

PBA30F Datasheet, PDF (1/2 Pages) RSG Electronic Components GmbH – Unit type
PB
R
Unit type
PBA30F
Ordering information
PB
1
A 30 F -O -O
2
3
4
5
6
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is pending for approval)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA30F-3R3
19.8
3.3V 6A
PBA30F-5
30
5V 6A
PBA30F-9
30.6
9V 3.4A
PBA30F-12
30
12V 2.5A
PBA30F-15
30
15V 2A
PBA30F-24
31.2
24V 1.3A
PBA30F-48
31.2
48V 0.65A
SPECIFICATIONS
MODEL
PBA30F-3R3 PBA30F-5
PBA30F-9
PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48
VOLTAGE[V]
CURRENT[A]
AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3)
ACIN 100V 0.50typ (Io=100%) 0.70typ (Io=100%)
ACIN 200V 0.30typ (Io=100%) 0.40typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
INPUT
EFFICIENCY[%]
ACIN 100V 68typ
ACIN 200V 69typ
74typ
77typ
75typ
77typ
76typ
78typ
78typ
81typ
78typ
81typ
79typ
81typ
ACIN 100V 15typ (Io=100%) (At cold start)
INRUSH CURRENT[A] ACIN 200V 30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
3.3
5
9
12
15
24
48
CURRENT[A]
6
6
3.4
2.5
2
1.3
0.65
LINE REGULATION[mV] 20max
20max
36max
48max
60max
96max
192max
LOAD REGULATION[mV] 40max
40max
100max
100max
120max
150max
240max
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C*1 140max
80max
140max
120max
160max
120max
160max
120max
160max
120max
160max
150max
200max
OUTPUT
RIPPLE NOISE[mVp-p] 0 to +50C*1 120max
-10 - 0C*1 160max
120max
160max
150max
180max
150max
180max
150max
180max
150max
180max
250max
300max
TEMPERATURE REGULATION[mV] 0 to +50C 50max
-10 to +50C 60max
50max
60max
90max
120max
120max
150max
150max
180max
240max
290max
480max
600max
DRIFT[mV]
*2 20max
20max
36max
48max
60max
96max
192max
START-UP TIME[ms]
HOLD-UP TIME[ms]
200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60
4.50 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
39.0 - 53.0
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] 4.00 - 5.25
CIRCUIT AND
OTHERS OPERATING INDICATION
LED (Green)
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
REMOTE ON/OFF
None
20.0 - 25.0
30.0 - 37.0
58.0 - 65.0
INPUT-OUTPUT
ISOLATION INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
-10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4)
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
31X78X103mm (without terminal block) (WXHXD) / 270g max (without cover)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
A-8
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.