MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA300F-3R3
198
ACIN 100V 3.3V 60A
ACIN 200V*3 3.3V 60A
PBA300F-5
300
5V 60A
5V 60A
PBA300F-7R5
300
7.5V 40A
7.5V 40A
PBA300F-12
324
12V 27A
12V 27A
PBA300F-15
330
15V 22A
15V 22A
PBA300F-24
336
24V 14A
24V 14(16.5)A
PBA300F-36
324
36V 9A
36V 9A
PBA300F-48
336
48V 7A
48V 7A
SPECIFICATIONS
MODEL
PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
VOLTAGE[V]
AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4)
CURRENT[A]
ACIN 100V 3typ
ACIN 200V 1.6typ
4.1typ
2typ
FREQUENCY[Hz]
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
ACIN 100V 68typ
ACIN 200V 71typ
74typ
77typ
76typ
79typ
78typ
81typ
78typ
81typ
79typ
82typ
81typ
84typ
79typ
82typ
POWER FACTOR
ACIN 100V 0.98typ (Io=100%)
ACIN 200V 0.95typ (Io=100%)
ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
INRUSH CURRENT[A] ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA]
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
3.3
5
7.5
12
15
24
36
48
ACIN 100V 60
60
40
27
22
14
9
7
CURRENT[A]
ACIN 200V*3 60
60
40
27
22
14(16.5)
9
7
LINE REGULATION[mV]
20max
20max
36max
48max
60max
96max
144max
192max
LOAD REGULATION[mV]
40max
40max
60max
100max
120max
150max
150max
300max
RIPPLE[mVp-p]
0 to +50C*1 80max
-20 - 0C*1 140max
80max
140max
120max
160max
120max
160max
120max
160max
120max
160max
150max
160max
150max
400max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1
-20 - 0C*1
120max
160max
120max
160max
150max
180max
150max
180max
150max
180max
150max
180max
200max
240max
200max
500max
TEMPERATURE REGULATION[mV] 0 to +50C*1 40max
-20 to +50C*1 60max
50max
75max
75max
120max
120max
180max
150max
180max
240max
290max
360max
440max
480max
600max
DRIFT[mV]
*2 12max
20max
30max
48max
60max
96max
144max
192max
START-UP TIME[ms]
HOLD-UP TIME[ms]
300typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100/200V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] 4.3 - 6.3
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
Provided
6.5 - 8.0
9.0 - 11.6
14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 43.2 - 54.0 57.6 - 80.0
REMOTE ON/OFF
Provided
INPUT-OUTPUT -RC
ISOLATION INPUT-FG
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature)
-20 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS (At only AC input)
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS
CE MARKING
HARMONIC ATTENUATOR
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
102X42X170mm (without terminal block and screw) (WXHXD) /1.0kg max
Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
* A sound may occur from power supply at pulse loading.
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Derating is required.Consult us for details.
Distribution:
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
A-18
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice