English
Language : 

PAA100F Datasheet, PDF (1/2 Pages) RSG Electronic Components GmbH – Unit type
PAA
R
Unit type
PAA100F
Ordering information
PAA 100 F -5 -O
1
2
3
4
5
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional
C :with Coating
G :Low leakage current
N :with Cover
R :with Remote ON/OFF
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PAA100F-3
60
3V 20A
PAA100F-5
100
5V 20A
PAA100F-12
102
12V 8.5A
PAA100F-15
105
15V 7A
PAA100F-24
108
24V 4.5A
PAA100F-48
100.8
48V 2.1A
SPECIFICATIONS
MODEL
PAA100F-3
PAA100F-5
PAA100F-12
PAA100F-15
PAA100F-24
PAA100F-48
VOLTAGE[V]
AC85 - 264 1f or DC120 - 340
CURRENT[A]
ACIN 100V 0.9typ
ACIN 200V 0.45typ
1.4typ
0.7typ
FREQUENCY[Hz]
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
POWER FACTOR
65typ
74typ
ACIN 100V 0.99typ (Io=100%)
ACIN 200V 0.95typ (Io=100%)
76typ
77typ
79typ
79typ
ACIN 100V 20typ (Io=100%) (At cold start)
INRUSH CURRENT[A] ACIN 200V 40typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
VOLTAGE[V]
3
5
12
15
24
48
CURRENT[A]
20
20
8.5
7
4.5
2.1
LINE REGULATION[mV] 20max
20max
48max
60max
96max
192max
LOAD REGULATION[mV] 40max
40max
100max
120max
150max
240max
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C*1 140max
80max
140max
120max
160max
120max
160max
120max
160max
150max
200max
OUTPUT
RIPPLE NOISE[mVp-p] 0 to +50C*1 120max
-10 - 0C*1 160max
120max
160max
150max
180max
150max
180max
150max
180max
400max
600max
TEMPERATURE REGULATION[mV] 0 to +50C 50max
-10 to +50C 60max
50max
60max
120max
150max
150max
180max
240max
290max
480max
600max
DRIFT[mV]
*2 20max
20max
48max
60max
96max
192max
START-UP TIME[ms]
500max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
20typ (Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
t10%
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION 4.00 - 5.25V
CIRCUIT AND OPERATING INDICATION LED (Green)
OTHERS REMOTE SENSING
Provided
Works at 115 - 140% of rating
REMOTE ON/OFF
Optional (Refer to Instruction Manual)
INPUT-OUTPUT -RC
*3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
INPUT-FG
ISOLATION
OUTPUT-RC-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
*3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
OUTPUT-RC
*3 AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
50X93X189mm (without terminal block) (WXHXD) /700g max (without cover)
Convection
*1 According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Applicable when Remote ON/OFF(optional) is added.
* Derating is required when operated with cover. Distribution:
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
A-52
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice