English
Language : 

LPS-75 Datasheet, PDF (1/2 Pages) Astrodyne Corporation – 75W Single Output Switching Power Supply
RSG■
ELECTRONIC COMPONENTS
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
75W Single Output Switching Power Supply
LPS-75 series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
PWM control and regulated
Small and compact size
Built-in remote ON-OFF control
LED indicator for power on
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
LPS-75-3.3
LPS-75-5
LPS-75-12
LPS-75-15
LPS-75-24
LPS-75-48
DC VOLTAGE
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
15A
15A
6.2A
5A
3.2A
1.56A
CURRENT RANGE
0 ~ 16.5A
0 ~ 16.5A
0 ~ 6.8A
0 ~ 5.5A
0 ~ 3.5A
0 ~ 1.7A
RATED POWER
49.5W
75W
74.4W
75W
76.8W
75W
PEAK LOAD(10sec.) Note.4 54.45W
82.5W
81.6W
82.5W
84W
81.6W
RIPPLE & NOISE (max.) Note.2 80mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
3 ~3.5V
80mVp-p
4.75 ~ 5.5V
100mVp-p
11 ~ 13.5V
100mVp-p
13.5 ~ 16.5V
120mVp-p
22 ~ 27V
120mVp-p
45 ~ 54V
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
2.0%
2.0%
2.0%
2.0%
LINE REGULATION
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
3.0%
3.0%
2.0%
2.0%
1.0%
1.0%
SETUP, RISE TIME
100ms, 35ms/230VAC 100ms, 35ms/115VAC at full load
HOLD TIME (Typ.)
60ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY(Typ.)
69%
77%
80%
81%
83%
83%
AC CURRENT (Typ.)
1.9A/115VAC 1.1A/230VAC
INRUSH CURRENT (Typ.) COLD START 18A/115VAC 36A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
115 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
27.6 ~ 32.4V
57.6 ~ 67.2V
FUNCTION REMOTE ON/OFF
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.04%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 5)
EMI CONDUCTION & RADIATION Compliance to EN55011, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A
MTBF
355Khrs min. MIL-HDBK-217F (25 )
DIMENSION
222*55*30mm (L*W*H)
PACKING
0.3Kg; 48pcs/15.6Kg/1.12CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:LPS-75-SPEC 2006-04-13