English
Language : 

LEB225F Datasheet, PDF (1/6 Pages) RSG Electronic Components GmbH – AC-DC Power Supplies Open Frame/ Enclosed type
LEB
AC-DC Power Supplies Open Frame/ Enclosed type
Ordering information
LEB100F
LEB 100 F -05 24 -O
1
2
3
4
5
6
1Series name
R
Recommended EMI/EMC Filter 2Output wattage
NAC-06-472
3Universal input
4V1 Output voltage
5V2 Output voltage
6Optional *1 *8
G :Low leakage current
R :with Remote ON/OFF
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
S :with Chassis
SN :with Chassis & cover
T :Vertical terminal block
Y :with Potentiometer
Z :with ZT
MODEL
DC OUTPUT
LEB100F-0512
V1
+5V 5A
V2
+12V 5(Peak 10)A
LEB100F-0324
+3.3V 5A
+24V 4(Peak 7)A
LEB100F-0524
+5V 5A
+24V 4(Peak 7)A
LEB100F-0530
+5V 5A
+30V 3.2(Peak 5.6)A
LEB100F-0536
+5V 5A
+36V 2.7(Peak 4.7)A
SPECIFICATIONS
MODEL
LEB100F-0512
LEB100F-0324
LEB100F-0524
LEB100F-0530
VOLTAGE[V]
CURRENT[A]
AC85 - 264 1f or DC 120 - 370
ACIN 100V 1.2typ (Io=100%)
1.4typ (Io=100%)
ACIN 200V 0.6typ (Io=100%)
0.7typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 63) or DC
INPUT
EFFICIENCY[%]
ACIN 100V 74typ (Io=100%)
ACIN 200V 76typ (Io=100%)
78typ (Io=100%)
80typ (Io=100%)
78typ (Io=100%)
80typ (Io=100%)
78typ (Io=100%)
80typ (Io=100%)
POWER FACTOR
ACIN 100V 0.98typ
ACIN 200V 0.93typ
0.99typ
INRUSH CURRENT[A]
ACIN 100V
ACIN 200V
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
LEAKAGE CURRENT[mA]
0.75max (60Hz, According to IEC60950 and DEN-AN)
VOLTAGE[V]
+5
+12
+3.3
+24
+5
+24
+5
+30
CURRENT[A]
*2 0 - 5
0 - 5 (Peak 10) 0 - 5
0 - 4 (Peak 7) 0 - 5
0 - 4 (Peak 7) 0 - 5
0 - 3.2 (Peak 5.6)
TOTAL OUTPUT WATTAGE[W] *3 85 (Peak 145)
100 (Peak 172)
100 (Peak 172)
100 (Peak 172)
LINE REGULATION[mV]
20max
48max
20max
96max
20max
96max
20max
120max
LOAD REGULATION[mV]
40max
100max 40max
150max 40max
150max 40max
180max
RIPPLE[mVp-p]
0 to +50C*4 80max
-10 - 0C*4 140max
120max
160max
80max
140max
120max
160max
80max
140max
120max
160max
80max
140max
200max
240max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*4
-10 - 0C*4
120max
160max
150max
180max
120max
160max
150max
180max
120max
160max
150max
180max
120max
160max
300max
360max
TEMPERATURE REGULATION[mV]
0 to +50C
-10 to +50C
50max
60max
120max
150max
50max
60max
240max
290max
50max
60max
240max
290max
50max
60max
300max
350max
DRIFT[mV]
*5 20max
48max
20max
96max
20max
96max
20max
120max
START-UP TIME[ms]
*6 250max 500max 250max 500max 250max 500max 250max 500max
HOLD-UP TIME[ms]
*6 40typ
20typ
40typ
20typ
40typ
20typ
40typ
20typ
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.5 - 5.5 Fixed
2.85 - 3.60 Fixed
4.5 - 5.5 Fixed
4.5 - 5.5 Fixed
OUTPUT VOLTAGE SETTING[V] xx
11.5 - 12.5 xx
23.0 - 25.0 xx
23.0 - 25.0 xx
28.7 - 31.5
OVERCURRENT PROTECTION V1
PROTECTION
V2
CIRCUIT AND
V1
OTHERS
OVERVOLTAGE PROTECTION V2
Works over 105% of rating current and recovers automatically
Works over 101% of peak current and recovers automatically
Works over 115% of rating, by zener diode clamping
Works at 115 - 140% of rating
REMOTE ON/OFF
Option (Refer to Instruction Manual)
INPUT-OUTPUT -RC
*7 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
ISOLATION INPUT-FG
OUTPUT-RC-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
*7 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
OUTPUT-OUTPUT(V1-RC-V2) *7 AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +70C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2 *9
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
75X35X222mm [2.95X1.38X8.74 inches] (WXHXD) /420g max (without chassis and cover)
Convection
LEB100F-0536
78typ (Io=100%)
80typ (Io=100%)
+5
+36
0-5
0 - 2.7 (Peak 4.7)
100 (Peak 172)
20max
144max
40max
180max
80max
200max
140max 240max
120max 300max
160max 360max
50max
300max
60max
350max
20max
144max
250max 500max
40typ
20typ
4.5 - 5.5 Fixed
xx
34.5 - 37.5
*1 Specification is changed at option, refer to Instruction Manual 5.
*2 Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 4. In detail.
*3 Refer to Instruction Manual 2.2 in detail.
*4 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*5 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*6 ACIN 100V,lo=100%
*7 Applicable when remote control (optional) is added.
*8 Please contact us about safety approvals for the model with option.
*9 Please contact us about class C.
* Series/Parallel operation is not possible.
* Derating is required when operated with chassis and cover.
* A sound may occur from power supply at peak loading.
LEB-2