English
Language : 

IQ-60 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 60W Isolated Quad Output Switching Power Supply
RSG■
ELECTRONIC COMPONENTS
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
60W Isolated Quad Output Switching Power Supply
IQ-60 series
Features :
Isolated output & GND for CH1,CH2 & CH3,CH4
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 67KHz
2 years warranty
SPECIFICATION
MODEL
IQ-60D
IQ-60F
OUTPUT
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
DC VOLTAGE
5V
12V
-12V
24V
5V
15V
-15V
24V
RATED CURRENT
3A
0.5A
0.5A
1.3A
3A
0.5A
0.5A
1.25A
CURRENT RANGE
0.5 ~ 3A
0.1 ~ 1A
0.1 ~ 1A
0.2 ~ 2A
0.5 ~ 3A
0.1 ~ 1A
0.1 ~ 1A
0.2 ~ 2A
RATED POWER
58.2W
60W
OUTPUT
PEAK LOAD (3sec.) Note.4 70W
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 3.0%
8.0%
LINE REGULATION
1.0%
2.0%
120mVp-p
8.0%
2.0%
240mVp-p
8.0%
2.0%
80mVp-p
150mVp-p
CH1 : 4.75 ~ 5.5V
3.0%
8.0%
1.0%
2.0%
150mVp-p
8.0%
2.0%
240mVp-p
8.0%
2.0%
LOAD REGULATION
2.0%
5.0%
5.0%
5.0%
2.0%
5.0%
5.0%
5.0%
SETUP, RISE TIME
300ms, 20ms/230VAC 800ms, 20ms/115VAC at full load
HOLD TIME (Typ.)
80ms/230VAC 18ms/115VAC at full load
INPUT
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
76%
1.8A/115VAC 0.9A/230VAC
COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
70 ~ 90W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )on +5V output
VIBRATION
SAFETY STANDARDS
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 5)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
OTHERS
EMS IMMUNITY
MTBF
DIMENSION
PACKING
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, Light industry level, criteria A
313K hrs min. MIL-HDBK-217F (25 )
159*97*38mm (L*W*H)
0.55Kg; 24pcs/14.2Kg/0.75CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 5% Duty cycle maximum within every 1min. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:IQ-60-SPEC 2006-08-01