English
Language : 

DRB15 Datasheet, PDF (1/5 Pages) RSG Electronic Components GmbH – 15W to 100W Single Output DIN Rail Mount Power Supplies
,QGXVWULDO
7HVW
%URDGFDVW
DRB Series
www.uk.tdk-lambda.com/drb
15W to 100W Single Output
DIN Rail Mount Power Supplies
Features
Benefits
• Compact Footprint • Saves Space on Rail & Cabinet Cost
• Efficiency up 91% • Cooler Applications - Improved Thermal Performance
• ErP Compliant Design • Better “Environmental Footprint”
Specification
Model
DRB15
DRB30
DRB50
DRB100
ITEMS
AC input voltage range
VAC
85-264 (withstand 300VAC for 5 sec)
Input frequency
Hz
47-63
Inrush cold (typ)
A
35A
40A
50A
40A
Power factor (typ) (110/230VAC)
0.55/0.42
0.56/0.46
0.6/0.5
0.98/0.93
Input current (typ)
A
0.27/0.17
0.55/0.33
0.9/0.55
1.2/0.6
Output voltage
V
24
12 / 24
5 / 12 / 24 / 48
24
Output current
A
0.63
2.5 / 1.25
6 /3.4 / 2.1 / 1.05
4.2
Line regulation
mV
240
120 / 240
50 / 150 / 240 / 480
240
Load regulation
mV
240
120 / 240
50 / 150 / 240 / 480
240
Ripple & noise (max) (typ)
mV
20
40 / 30
30 / 20 / 30 / 40
30
Over current protection
Hiccup with auto recovery
Over voltage protection (1) 5V: 115%-135%, 12V: 133%-156%, 24V: 125%-140%, 48V: 112%-142% (latch mode)
Hold up time (230VAC)
ms
20 @100VAC, full load, 25°C
Efficiency (typ) (230VAC)
%
90
88 / 90
80 / 90 / 90 / 91
91
Average efficiency (230VAC)
%
88
87/89
5V:n/a, 12V:88, 24V:87, 48V:87
87
No load power
W
<0.3
<0.3
<0.3
<0.5
Parallel operation
Not available
Serial operation
Possible
LED indicators
DC OK signal - green
Operating temperature (2, 3, 5) °C
-20°C to +70°C ( see derating curves)
Storage temperature
°C
-40°C to +85°C
Operating humidity
5-95% RH (non condensing)
Cooling (4)
Convection
Withstand voltage
Input - Output : 3.0kVAC (20mA), Input - FG : 1.5kVAC (20mA)
Output - FG : 500VAC (100mA) 1 min.
Isolation resistance
MΩ
Input-FG, Input-Output & Output-FG: More than 100MΩ (500VDC) at 25°C and 70%RH
Vibration
Non-operating,10-55Hz(sweep for 1 min.):19.6 m/s2 (2G) Constant, X,Y,Z each 1hr
Shock
294m/s2(30G) 11ms half sine
Safety agency approvals
UL60950-1, CSA22.2 No.60950-1 (2nd edition), EN60950-1, UL508
Emissions
EN55022, CISPR22 class B
Immunity
EN61000-4-2,-3,-4,-5,-6,-8,-11
Weight (typ)
g
85
95
175
300
Size (W x H x D)
mm
18 x 75 x 90
21x75x90
30x75x90
45x75x100
Case material
Flame Retardant Polycarbonate (UL94 V-0)
Warranty
yrs
3
Notes:
1 Output will shutdown, manual reset required (power off then on)
2 Refer to output derating curves
3 For UL508 operating temperature refers to surrounding air temperature
4 See installation instructions for mounting orientation
5 Low temperature start up: -40°C typical
DRB Series
1