English
Language : 

DPG500 Datasheet, PDF (1/2 Pages) RSG Electronic Components GmbH – AC-DC Power Supplies Power Module type
AC-DC Power Supplies Power Module type
DPG
Ordering information
DPG 750
1
2
1Series name
2Output power
500 : 500W (ACIN 200V)
750 : 750W (ACIN 200V)
DPG
MODEL
AC INPUT[V]
MAX OUTPUT WATTAGE[W]
DC OUTPUT VOLTAGE[V]
DPG500
AC85 - 264
*1 300
*2 360
AC170 - 264
500
DPG750
AC85 - 264
500
AC170 - 264
750
SPECIFICATIONS
MODEL
DPG500
VOLTAGE[V]
AC85 - 264 1f
POWER FACTOR CORRECTION RANGE[V] AC85 - 264 1f
AC170 - 264 1f
DPG750
AC85 - 264 1f
AC170 - 264 1f
CURRENT[A]
3.47typ (ACIN 100V)
2.86typ (ACIN 200V)
5.72typ (ACIN 100V)
4.24typ (ACIN 200V)
INPUT
FREQUENCY[Hz]
INRUSH CURRENT[A]
50/60 (47 - 63) Hz
Limited by external resistance
EFFICIENCY[%]
92typ (ACIN 100V)
95typ (ACIN 200V)
93typ (ACIN 100V)
96typ (ACIN 200V)
POWER FACTOR
0.96typ (ACIN 100V)
0.93typ (ACIN 200V)
0.96typ (ACIN 100V)
0.93typ (ACIN 200V)
LEAKAGE CURRENT[mA] 0.75 max (60Hz, According to IEC60950 and DEN-AN)
WATTAGE[W]
*1 300
500
500
750
OUTPUT VOLTAGE[V]
*2 360
VOLTAGE ACCURACY *3 ±2%
PROTECTION OVERVOLTAGE PROTECTION[V] DC400 - 450V The power factor corrector function stops
CIRCUIT AND ENA
*4 Enable signal, Open-drain output, Maximum sink current 10mA, Maximum allowance voltage 35V
OTHERS
OTHERS
*5 Parallel operation impossible , Thermal protection
INPUT-OUTPUT
ISOLATION
INPUT, OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
Non isolated
AC2,800V 1minute Cutoff current = 10mA, DC500V, 50MW min (20±15C)
-40 to +85C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY
OTHERS
AGENCY APPROVALS
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1
Complies with IEC61000-3-2 *6
58.4X12.7X61mm [2.3X0.5X2.4 inches] (WXHXD) / 100g max
Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to Input voltage derating.
*2 When the input voltage is more than 240V, the output voltage becomes the value proportional to the input voltage.
*3 The value included the output setting and the line regulation, the load regulation and the temperature regulation.
However, the input voltage is less than 240V.
*4 Refer to the instruction Manual.
*5 The thermal protection stops the power factor corrector function and the ENA signal.
*6 Please contact us about class C.
DPG-2