ADA600F Datasheet, PDF (1/2 Pages) RSG Electronic Components GmbH – Hight power & peak power, Parallel / master-slave / N+1 redundant (optional), Current monitor, up to 5 years warranty
Distribution:
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany
Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
Unit type
Ordering information
ADA
ADA600F
ADA 600 F -24 -O
1
2
3
4
5
1Series name
R
Recommended Noise Filter 2Output wattage
NAC-20-472
3Universal input
4Output voltage
5Optional
G :Low leakage current
E :Low leakage current
and EMI class A
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
F :with Fan unit(only -24)
T :Vertical terminal block
J :Connector type
C :with Coating
R :Remote ON/OFF
N1:DIN rail
W:Alarms and Redundant
operation
Specification is changed at
option,refer to Instruction
Manual.
Please refer to derating curve, because the rated load current depends on cooling method that is convention cooling or forced air.
SPECIFICATIONS
MODEL
ADA600F-24
ADA600F-30
ADA600F-36
ADA600F-48
VOLTAGE[V]
FREQUENCY[Hz]
AC85 - 264 1f or DC 120 - 350 (AC64 or DC90 optionally available *6)
50/60 (47 - 63) or DC
EFFICIENCY[%]
ACIN 100V 84typ (Io=100%)
ACIN 200V 86typ (Io=100%)
86typ (Io=100%)
87typ (Io=100%)
86typ (Io=100%)
87typ (Io=100%)
86typ (Io=100%)
89typ (Io=100%)
INPUT
ACIN 100V 0.99typ (Io=100%)
POWER FACTOR ACIN 200V 0.98typ (Io=100%)
INRUSH
CURRENT[A]
ACIN 100V*1
ACIN 200V*1
20typ
40typ
(Io=100%)
(Io=100%)
(More
(More
than
than
3sec.to
3sec.to
re-start)
re-start)
LEAKAGE CURRENT[mA] 0.75max (60Hz, According to IEC60950 and DEN-AN) (Io=100%)
VOLTAGE[V]
24
30
36
48
ACIN 100V*2 14 (Peak 25) convection 11 (Peak 20) convection 9 (Peak 16.5) convection 6.5 (Peak 12.5) convection
CURRENT[A]
ACIN 100V*2 21 (Peak 25) forced air
ACIN 200V*2 15 (Peak 31) convection
16.5 (Peak 20) forced air 14 (Peak 16.5) forced air 10.5 (Peak 12.5) forced air
12 (Peak 24.5) convection 10 (Peak 20.5) convection 7 (Peak 15.5) convection
ACIN 200V*2 25 (Peak 31) forced air
20 (Peak 24.5) forced air 16.5 (Peak 20.5) forced air 12.5 (Peak 15.5) forced air
LINE REGULATION[mV] 96max
120max
144max
192max
LOAD REGULATION[mV] 150max
180max
240max
300max
RIPPLE[mVp-p]
OUTPUT
0 to +50C*3 120max
-10 - 0C*3 160max
160max
230max
200max
260max
200max
300max
RIPPLE NOISE[mVp-p] 0 to +50C*3 150max
-10 - 0C*3 180max
190max
250max
230max
280max
250max
400max
TEMPERATURE REGULATION[mV] 0 to +50C 240max
300max
360max
480max
DRIFT[mV]
*4 96max
120max
144max
192max
START-UP TIME[ms]
500max (ACIN 100V, Io=100%)
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.6 - 27.0
27.0 - 33.0
33.0 - 41.0
41.0 - 52.8
OUTPUT VOLTAGE SETTING[V] 23.5 - 24.5
29.0 - 31.0
35.0 - 37.0
47.0 - 49.0
OVERCURRENT PROTECTION Works over 101% of peak current and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] 31 - 34.5
40 - 48
51 - 60
64 - 76
CIRCUIT AND OPERATING INDICATION LED (Green)
OTHERS ALARM OUTPUT
Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5)
REMOTE ON/OFF(RC)
Requirement for external source (Option : -R, refer to Instruction Manual 5)
INPUT-OUTPUT -RC
*5 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
ISOLATION INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
OUTPUT-RC-FG
*5 AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
HARMONIC ATTENUATOR
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
65X127X195mm (WXHXD) (without terminal block) /1.5kg max
Convection/Forced air
*1 The value is primary surge.The current of input surge to a built-in noise filter (0.2ms or less) is
excluded.
*2 Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown
in Instruction Manual 2.3.
*3 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*5 Applicable when remote control (optional) is added.
*6 Derating is required.Consult us for details.
* A sound may occur from power supply at pulse loading.