Technical Data Sheet - Draft
Power cable connection
SLPCC001-C05N
Electrical data
Current handling (40 °C ambient temp.)
Surge current handling
Working voltage
- Limitations are possible due to the used cable type -
40 A
50 kA, 10/350 µs test pulse
60 V DC
Mechanical data
Cable captivation
≥ 1.0 kN
Environmental data
Temperature range
Rapid change of temperature
Corrosion resistance
Vibration
Damp heat
Degree of protection (mated pair)
RoHS
-40 °C to +85 °C
DIN EN 122190, Sub-clause 4.6.7
DIN EN 122190, Sub-clause 4.6.10
DIN EN 122190, Sub-clause 4.6.3
DIN EN 122190 , Sub-clause 4.6.6
IEC 60529, IP67
compliant
Suitable cables
Feeder side:
Power side:
Packing
Standard
Weight
RosenbergerSLinkTM 7/8”R (recommended)
Leoni 7/8" R
RFS LCF 78/50
Andrew LDF 5-50A
Draka RFA 7/8-50
Acome HPL50-7/8
Eupen 5228
LS 22D
NYCWY 2 x 16 re/16 (recommended)
(further cables will be tested)
1 pcs in box
445.4 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Martin Wimmer 29.04.2013
Approved
J. Peteranderl
Date
20.01.2014
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Rev. Engineering change number
500
13-v659
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
Name
S. Krautenb.
Date
20.01.14
Page
2/2