English
Language : 

71S170-C10S3 Datasheet, PDF (2/3 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Calibration Load Plug
Technical Data Sheet
BNC
75 Ω
Calibration Load
Plug
Electrical data
Frequency range
Return loss
Power handling
71S170-C10S3
DC to 4 GHz
≥ 35 dB, DC to 2 GHz
≥ 30 dB, 2 GHz to 4 GHz
≤ 0.5 W
Mechanical data
Mating cycles
Gauge
≥ 500
5.31 mm to 5.38 mm
General standard definitions
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Zo / Impedance / Zo
Offset Delay
Length (electrical) / Offset Length
Offset Loss
Loss
75 Ω
0.0000 ps
0.000 mm
0.00 GΩ/s
0.0000 dB/ GHz
Environmental data
Operating temperature range1
Rated temperature range of use2
Storage temperature range
+20 °C to +26 °C
0 °C to +50 °C
-40 °C to +85 °C
RoHS
compliant
1 Temperature range over which these specifications are valid.
2 This range is underneath and above the operating temperature range, within the open circuit is fully functional
and could be used without damage.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Fax : +49 8684 18-1499
Email : info@rosenberger.de
Page
2/3