English
Language : 

60S34R-MSON3 Datasheet, PDF (2/3 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Calibration Kit
Technical Data Sheet
7-16
Calibration Kit
Plug
60S34R-MSON3
Electrical data
Frequency range
DC to 4 GHz
Open
Return loss
Error from nominal phase1
≤ 0.15 dB, DC to 4 GHz
≤ 3.0°, DC to 4 GHz
Short
Return loss
Error from nominal phase1
≤ 0.15 dB, DC to 4 GHz
≤ 3.0°, DC to 4 GHz
Load
Return loss
DC Resistance
Power handling
≥ 40 dB, DC to 2.5 GHz
≥ 38 dB, 2.5 GHz to 4 GHz
50 Ω ± 0.5 Ω
≤ 1.0 W
1 The nominal phase is defined by the Offset Delay, the Offset Loss and the Fringing Capacitances
2 The nominal phase is defined by the Offset Delay, the Offset Loss and the Short Inductance
Mechanical data
Mating cycles
Maximum torque
Recommended torque
Gauge
≥ 500
30 Nm
2.26 Nm
1.47 mm to 1.77 mm
General standard definitions
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Open
Offset Zo / Impedance / Zo
Offset Delay
Length (electrical) / Offset Length
Offset Loss
Loss
Fringing Capacitances
50 Ω
56.372 ps
16.90 mm
0.50 GΩ/s
0.0049 dB/ GHz
C0 = 168.000 x 10-15 F
/
C1 = 2600.00 x 10-27 F/Hz /
C2 = 50.0000 x 10-36 F/Hz2 /
C3 = 0.80000 x 10-45 F/Hz3 /
168.000 fF
2.60000 fF /GHz
0.05000 fF /GHz2
0.00080 fF /GHz3
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de