English
Language : 

60S131-272B1 Datasheet, PDF (2/2 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – 7/16 STRAIGHT PLUG
TECHNICAL DATA SHEET
7/16
STRAIGHT PLUG
60S131-272B1
Electrical data
Impedance
Frequency
Return loss
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Working voltage (at sea level)
RF-leakage
Intermodulation (3rd order)
50 
DC to 7.5 GHz
 35 dB, DC to 1 GHz
 30 dB, 1 GHz to 2.5 GHz
 25 dB, 2.5 GHz to 5 GHz
 0.05 dB
 104 M
 0.4 m
 1.5 m
500 V rms, 50 Hz
 128 dB up to 1 GHz
 -115 dBm @ 2 x 20 W
- Limitations are possible due to the used cable type -
Mechanical data
Mating cycles
Center contact captivation: axial
radial
Coupling torque (recommended)
Proof torque
 500
 200 N
 2 Ncm
25 to 30 Nm
max. 35 Nm
Environmental data
Temperature range
Rapid change of temperature
Corrosion salt mist
Vibration
Damp heat
Climatic tests
Degree of protection (mated pair)
RoHS
Tooling
-55°C to +155°C
DIN EN 122190, clause 4.6.7
DIN EN 122190, clause 4.6.10
DIN EN 122190, clause 4.6.3
DIN EN 122190, clause 4.6.6
DIN EN 122190, clause 4.6.5 (55/155/56)
IEC 60529, IP67
compliant
N/A
Suitable cables
RTK-FS 141, UT 141, RG 402
Weight
Weight
97 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Hauke Schütt 19/04/05 J_Gramsamer 07.04.15
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Rev. Engineering change number
e00
15-0397
Tel.: +49 8684 18-0
email: info@rosenberger.de
Name
J_Krautenb.
Date
07.04.15
Page