English
Language : 

60HK565-K00N1 Datasheet, PDF (2/2 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – SURGE ARRESTER JACK - JACK
Technical Data Sheet
7/16
SURGE ARRESTER
JACK - JACK
60HK565-K00N1
Electrical data
Impedance
Operating frequency
Return Loss
Insertion Loss
Center contact resistance
Outer contact resistance
Power handling (at 20 °C, sea level, VSWR 1.0)
RF-leakage
Intermodulation (3rd Order)
Nominal impulse discharge current
Residual voltage
Residual energy
50 
698 to 2700 MHz
 21 dB, 698 to 800 MHz
 26 dB, 800 to 960 MHz
 21 dB, 960 to 1700 MHz
 24 dB, 1700 to 2500 MHz
 21 dB, 2500 to 2700 MHz
 0.1 dB
< 0.4 m
< 1.5 m
1.8 KW @ 1 GHz
 128 dB @ 1 GHz
< -117 dBm @ 2 x 20 W
25 kA (8/20 µs)
< 160 V @ 20kA, 8/20 µs
< 15 V @ 4kV 1.2/50µs, 2kA 8/20 µs
< 30 µJ @ 4kV 1.2/50µs, 2kA 8/20 µs
Mechanical data
Mating cycles
Coupling nut retention
Center contact captivation: axial
radial
Coupling torque (recommended)
Proof torque
min. 500
 1000 N
 200 N
 2 Ncm
25 to 30 Nm
max. 35 Nm
Environmental data
Temperature range
Rapid change of temperature
Corrosion salt mist
Vibration
Shock
Climatic class
Cold
Dry heat
Damp heat (steady state)
Degree of protection (mated pair)
RoHS
-45°C to +85°C
IEC 60068-2-14 Test Na
IEC 60068-2-11 Test Ka
IEC 60068-2-6 Test Fc
IEC 60068-2-27 Test Ea
IEC 60068-1 (45/85/56)
IEC 60068-2-1 Test A
IEC 60068-2-2 Test B
IEC 60068-2-3 Test Ca
IEC 60529, IP68, mated condition
compliant
Weight
Weight
260 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Approved
Date
Martin Wimmer 17/10/11 Sa. Krautenbacher 20.03.14
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Rev. Engineering change number
b00
14-0352
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Name
T. Krojer
Date
20.03.14
Page
2/2