Technical Data Sheet
7-16
Calibration Kit
Full Version
60CK001-150
Documentation
This kit is delivered with
• USB-Stick
Standard Definitions as data files for Vector Network Anaylzer Families PNA (Keysight/Agilent) and ZVA
(Rohde&Schwarz). Calibration Certificate as PDF-file.
• Standard Definitions Cards
Printed Standard Definitions that can be used on nearly all Vector Network Analyzers.
• Kit Info Card
Handling precautions and information for installing Standard Definitions on a Vector Network Analyzer.
• Calibration Certificate
Details see “Declaration of calibration options”
• Operating Manual
Electrical specifications
This specification covers electrical key values for the main calibration standards of the calibration kit.
Specific datasheets are available for each component among the part number.
Calibration standard
Frequency
Parameter
Specification
Opensb
(plug and jack)
DC to ≤ 4 GHz
> 4 GHz to ≤ 8 GHz
Error from
Nominal Phase
≤ 1.0°
≤ 1.5°
Shortsb
(plug and jack)
DC to ≤ 4 GHz
> 4 GHz to ≤ 8 GHz
Error from
Nominal Phase
≤ 1.0°
≤ 1.5°
Calibration loads
(plug and jack)
DC to ≤ 4 GHz
> 4 GHz to ≤ 8 GHz
Return Loss
≥ 40 dB
≥ 38 dB
Calibration adaptors
(plug/plug)
DC to ≤ 4 GHz
> 4 GHz to ≤ 8 GHz
Return Loss
≥ 40 dB
≥ 36 dB
Calibration adaptors
(jack/jack)
DC to ≤ 4 GHz
> 4 GHz to ≤ 8 GHz
Return Loss
≥ 38 dB
≥ 34 dB
Calibration adaptors
RPC-N to 7-16
(plug/plug and jack/jack)
DC to ≤ 4 GHz
> 4 GHz to ≤ 8 GHz
Return Loss
≥ 36 dB
≥ 33 dB