English
Language : 

03S110-K21S3 Datasheet, PDF (2/3 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Calibration Adaptor
Technical Data Sheet
Calibration Adaptor
RPC-3.50 Plug – RPC-SP Jack
Electrical data
Frequency
Return loss
03S110-K21S3
DC to 22 GHz
≥ 34 dB, DC to 4 GHz
≥ 26 dB, 4 GHz to 22 GHz
Mechanical data
Mating cycles
Maximum torque
Recommended torque
Engagement force
Disengagement force
Gauge
RPC-3.50
≥ 500
1.70 Nm
0.90 Nm
0.00 mm to 0.08 mm
RPC-SP
≥ 1000
n.a. (no sliding outer conductor)
n.a. (no sliding outer conductor)
3.12 mm to 3.22 mm
General standard definition
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Zo / Impedance / Zo
Offset Delay
Length (electrical) / Offset Length
Offset Loss
Loss
50 Ω
70.8001 ps
21.23 mm
3.60 GΩ/s
0.0221 dB/ GHz
Environmental data
Operating temperature range1
Rated temperature range of use2
Storage temperature range
+ 20 °C to +26 °C
0 °C to +50 °C
- 40 °C to +85 °C
RoHS
compliant
1 Temperature range over which these specification are valid.
2 This range is underneath and above the operating temperature range, within the calibration adaptor is fully functional
and could be used without damage.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page