English
Language : 

03K150-G300 Datasheet, PDF (2/3 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Sliding Load Jack
Technical Data Sheet
RPC-3.50
Sliding Load
Jack
Electrical data
Frequency range
Return loss
Power handling
Air line accuracy
Repeatability of sliding position
03K150-G300
4 GHz to 26.5 GHz
 26.4 dB, 4 GHz to 5 GHz
 32 dB, 5 GHz to 26.5 GHz
≤1W
 50 dB
 60 dB, 4 GHz to 26.5 GHz
Mechanical data
Mating cycles
Maximum torque
Recommended torque
Gauge
 500
1.70 Nm
0.90 Nm
adjustable
General standard definitions
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Zo / Impedance / Zo
Min. Frequency
50 
4 GHz
Environmental data
Operating temperature range1
Rated temperature range of use2
Storage temperature range
+20 °C to +26 °C
0 °C to +50 °C
-40 °C to +85 °C
RoHS
compliant
1 Temperature range over which these specification are valid.
2 This range is underneath and above the operating temperature range, within the sliding load is fully functional
and could be used without damage.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page