03K150-055S3 Datasheet, PDF (2/2 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Mismatch Jack
Technical Data Sheet
RPC-3.50
Mismatch
Jack
Electrical data
Frequency range
VSWR
DC Resistance
Power handling
03K150-055S3
DC to 26.5 GHz
1.1 0.03, DC to 12 GHz
1.1 0.05, 12 GHz to 26.5 GHz
55 
≤ 0.5 W
Mechanical data
Mating cycles
Maximum torque
Recommended torque
Gauge
 500
1.70 Nm
0.90 Nm
0.00 mm to 0.04 mm
Environmental data
Operating temperature range1
Rated temperature range of use2
Storage temperature range
+20 °C to +26 °C
0 °C to +50 °C
-40 °C to +85 °C
RoHS
compliant
1 Temperature range over which these specification are valid.
2 This range is underneath and above the operating temperature range, within the mismatch is fully functional
and could be used without damage.
Declaration of calibration options
Factory Calibration
Standard delivery for this calibration standard includes a Factory Calibration. The Calibration Certificate issued
reports individual calibration results, traceable to national / international standards.
Accredited Calibration
Optional this calibration standard can be delivered with an Accredited Calibration (DAkkS) having the highest
confidence in the traceability. The DAkkS Calibration Certificate issued reports individual calibration results in
a complex format, traceable to national / international standards. Calibration results are reported in a dense
data set file. The uncertainties are smaller than in a Factory Calibration.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Calibration interval
Recommendation
12 months
Packing
Standard
Weight
1 pce in box
8.0 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Herbert Babinger
Date
17.10.14
Approved
Martin Moder
Date
17.10.14
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Rev.
e00
Engineering change number
14-1492
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Name
Herbert Babinger
Date
17.10.14
Page
2/2