English
Language : 

02K119-K20D3 Datasheet, PDF (2/3 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Calibration Adaptor
Technical Data Sheet
Calibration Adaptor
RPC-2.92 Jack – SMP Jack
Electrical data
Frequency
Return loss
Mechanical data
Mating cycles
Maximum torque
Recommended torque
Engagement force
Disengagement force
Gauge
02K119-K20D3
DC to 40 GHz
≥ 32 dB, DC to 12 GHz
≥ 26 dB, 12 GHz to 26.5 GHz
≥ 21 dB, 26.5 GHz to 40 GHz
RPC-2.92
≥ 500
1.70 Nm
0.90 Nm
0.00 mm to 0.03 mm
SMP
≥ 100 if mating part is full detent
≥ 500 if mating part is limited detent
≥ 1000 if mating part is smooth bore
Full detent 68 N
Limited detent 45 N
Smooth bore 9 N
Full detent 22 N
Limited detent 9 N
Smooth bore 2.2 N
0.00 mm to 0.05 mm
General standard definition
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Zo / Impedance / Zo
Offset Delay
Length (electrical) / Offset Length
Offset Loss
Loss
50 Ω
51.402 ps
15.41 mm
4.00 GΩ/s
0.0179 dB/ GHz
Environmental data
Operating temperature range1
Rated temperature range of use2
Storage temperature range
+20 °C to +26 °C
0 °C to +50 °C
-40 °C to +85 °C
RoHS
compliant
1 Temperature range over which these specifications are valid.
2 This range is underneath and above the operating temperature range, within the open circuit is fully functional
and could be used without damage.
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page